Difference between revisions of "Mar 17, 2022 - Update Meeting"
Jump to navigation
Jump to search
Line 14: | Line 14: | ||
* The electrodes and anode have been vacuum degassed to 950 C for 6 hours by S. Williams with the resulting sun profile shown below. | * The electrodes and anode have been vacuum degassed to 950 C for 6 hours by S. Williams with the resulting sun profile shown below. | ||
** [[File:InjElectDeg950_6hrs_031522_1040_data_plot.jpg]] | ** [[File:InjElectDeg950_6hrs_031522_1040_data_plot.jpg]] | ||
− | + | * The electrode have been store din containers ready for UHV cleaning in the production chem room just prior to assembly. | |
+ | *[[File:Electrodes in containers after 950 C vacuum degassing.jpg]] | ||
+ | * The ball electrode after the vacuum degassing run profile shown above (950 C for h) | ||
+ | *[[File:Electrode ball after 950 C for 6 hours vacuum degassing.jpg]] | ||
[https://wiki.jlab.org/ciswiki/index.php/Update_meetings Back to Update Meetings] | [https://wiki.jlab.org/ciswiki/index.php/Update_meetings Back to Update Meetings] |
Revision as of 08:51, 17 March 2022
Agenda
- NEG screens - Marcy
- Vacuum chamber
- Phil - Anything else to be done to the chamber (fiducial fixtures? support base? etc.)
- How is the vacuum bake going? Marcy / Phil
- Gun table layouts (UITF, CEBAF) - Shaun
- Anode tube versions
- Shaun sent Gabriel models for the 12 narrow and for the 6 wide slot tubes
- Gabriel has done simulation of the beam deflection with these 2 models. Slides can be found here
- The 12 slot tube seems to have a lesser effect on beam kick compared to the 6 slot tube
- Gabriel and Carlos will discuss next week with Joe results from electrostatic models with various biasing options. This is to pick the best tube version (12 narrow slots, or 6 wide slots)
- These are the models for the anode drift tube with 12, 0.5 inch wide slots (blue) and another tube with 6, 1.0 inch wide slots.
- The electrodes and anode have been vacuum degassed to 950 C for 6 hours by S. Williams with the resulting sun profile shown below.
- The electrode have been store din containers ready for UHV cleaning in the production chem room just prior to assembly.
- The ball electrode after the vacuum degassing run profile shown above (950 C for h)