Mar 17, 2022 - Update Meeting

From Ciswikidb
Revision as of 08:51, 17 March 2022 by Chgarcia (talk | contribs)
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Agenda

  • NEG screens - Marcy
  • Vacuum chamber
    • Phil - Anything else to be done to the chamber (fiducial fixtures? support base? etc.)
    • How is the vacuum bake going? Marcy / Phil
  • Gun table layouts (UITF, CEBAF) - Shaun
  • Anode tube versions
    • Shaun sent Gabriel models for the 12 narrow and for the 6 wide slot tubes
    • Gabriel has done simulation of the beam deflection with these 2 models. Slides can be found here
    • The 12 slot tube seems to have a lesser effect on beam kick compared to the 6 slot tube
    • Gabriel and Carlos will discuss next week with Joe results from electrostatic models with various biasing options. This is to pick the best tube version (12 narrow slots, or 6 wide slots)
  • These are the models for the anode drift tube with 12, 0.5 inch wide slots (blue) and another tube with 6, 1.0 inch wide slots.
  • Tilted anode and tube with 12 and with 6 slots.png
  • The electrodes and anode have been vacuum degassed to 950 C for 6 hours by S. Williams with the resulting sun profile shown below.
    • InjElectDeg950 6hrs 031522 1040 data plot.jpg
  • The electrode have been store din containers ready for UHV cleaning in the production chem room just prior to assembly.
  • Electrodes in containers after 950 C vacuum degassing.jpg
  • The ball electrode after the vacuum degassing run profile shown above (950 C for h)
  • Electrode ball after 950 C for 6 hours vacuum degassing.jpg

Back to Update Meetings