March 12, 2020 - ME/INJ/CIS

From Ciswikidb
Revision as of 07:08, 11 March 2020 by Grames (talk | contribs)
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
Mechanical
  • What is the bellows type count, how may 3" and 3.5"?
  • Chris, do you have all as-founds you need?
  • Use C channel everywhere and move pedestals ok?
Anthony says yes, do it
  • Carlos, send Shaun Wien feedthrough p/n
  • SS or Al brackets?
Use Al, now all 7-3/4" girder to beam line, girder holes whereever imagine support
  • NEG chambers
Detail Y- 10" flange, NEG's here
Flip DP for IP beam left, modify for new NEG's?
  • Laser vacuum window?
Caryn started evaluating
Layout tight, how to fit optics, inside laser room?
  • 2I spools?
ME will order, need in time to a) weld capture solenoid, b) NEG coat
  • New BPM's
Design done, feedthroughs ordered, waiting on req to MDC
  • Solenoid fixtures?
Magnets
  • Dipole
Emerson backed out, Milhous quoting round/square, Lakshimi working on Jay's AT design
  • Soleonids
Joe M. what is status?
  • Quads
Have 3 QW, Mike testing 2 spare QW quads (capture on welded cross)
  • Correctors
Joe G make tally
  • Wien
Technicoil getting ready to wind
  • PSS Kicker
Met w/ Jerry, Lakshimi working on upgraded kicker to move 200 keV beam 1cm @ 30 cm w < 200 mA (March 9 layout)
Orders
  • Bellows - waiting on final count
  • Right angle valves - we have 5 or 6, should be ok?
  • Gun 10" flange - signed req for (2)
  • BPM feedthroughs - ordered
  • BPM cans - waiting on req to MDC
Controls
  • Chris, what cameras will you use, will they fit?
  • Mark/Dave, do you have a plan for 2500W solid state chopper amps?
  • Mark/Dave, do you have a plan for Brock prebuncher cavity/amp?
  • Omar, do you have BPM channel?
Yes!
Modelers
  • Is the March 9th layout ok?
  • Is the harp location OK for solenoid scans?
  • Should a viewer remain at the harp location, should this be a YAG?
  • Where else should YAG's go?
  • Can a YAG go at the laser screen, I don't think so?
  • Is the beam envelope OK for ways we run spin rotators?
What are the currents and/or B's for the solenoids and quads?
  • What are the power levels for existing or Brock prebuncher cavities, for 130 or 200 keV locations?
  • Is distance from MFG1I04A to upstream corrector far enough? or move MFG1I04A downstream, how far?
Jay is running cases
  • Is the corrector/bpm downstream A1 useful?
Commissioning
  • Plan for May gun work?