Difference between revisions of "November 12, 2019 - AIPINJ modeling meeting"
Jump to navigation
Jump to search
(→Topics) |
|||
(4 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
== Topics == | == Topics == | ||
− | *Status update | + | ;Booster region |
− | + | * Status update evaluating desired buncher location? [[media:UpgradeInjectorGPTOptimizations_Buncher_2019_11_12.pdf]] | |
− | |||
− | |||
− | |||
; Gun to Chopper Model | ; Gun to Chopper Model | ||
− | * Start with the functional layout (sequence is important, maintain prebuncher near center of gun-chopper) | + | * Start with the functional layout (sequence is important, maintain prebuncher near center of gun-chopper) [https://wiki.jlab.org/ciswiki/index.php/AIPINJ_Layouts see layouts here] |
* Use "tee" electrode field map (what is extent of R,Z in model?) [https://wiki.jlab.org/ciswiki/index.php/Electrodes,_Insulators_and_HV_cable_inventories_and_drawings see types here] | * Use "tee" electrode field map (what is extent of R,Z in model?) [https://wiki.jlab.org/ciswiki/index.php/Electrodes,_Insulators_and_HV_cable_inventories_and_drawings see types here] | ||
− | * 15 deg bend - Implement new model (note, there are air- and steel- models) [[media:191111_JB_15dipole.pdf]] | + | * 15 deg bend - Implement new model (note, there are air- and steel- models) [[media:191112_15bend.pdf]] [[media:191111_JB_15dipole.pdf]] |
* Wien filter - Old and new models should be similar (yes?), but do we implement new model [https://wiki.jlab.org/ciswiki/index.php/Wien_Filter_References new model] | * Wien filter - Old and new models should be similar (yes?), but do we implement new model [https://wiki.jlab.org/ciswiki/index.php/Wien_Filter_References new model] | ||
* Should we identify match point after gun (for Elegant) and before chopper (for GPT simulations) | * Should we identify match point after gun (for Elegant) and before chopper (for GPT simulations) | ||
+ | |||
+ | ; Prebuncher at 130 kV and 200 kV | ||
+ | * Can prebuncher operate in new location @ 130 keV? | ||
+ | * What power level is needed @ 200 keV? |
Latest revision as of 13:23, 12 November 2019
Topics
- Booster region
- Status update evaluating desired buncher location? media:UpgradeInjectorGPTOptimizations_Buncher_2019_11_12.pdf
- Gun to Chopper Model
- Start with the functional layout (sequence is important, maintain prebuncher near center of gun-chopper) see layouts here
- Use "tee" electrode field map (what is extent of R,Z in model?) see types here
- 15 deg bend - Implement new model (note, there are air- and steel- models) media:191112_15bend.pdf media:191111_JB_15dipole.pdf
- Wien filter - Old and new models should be similar (yes?), but do we implement new model new model
- Should we identify match point after gun (for Elegant) and before chopper (for GPT simulations)
- Prebuncher at 130 kV and 200 kV
- Can prebuncher operate in new location @ 130 keV?
- What power level is needed @ 200 keV?