== Charge == | == Charge == | ||
− | Evaluate the | + | Evaluate the UITF design with respect to beam requirements for HDIce. |
+ | |||
1. Beam Optics - Can UITF deliver the beam HDIce needs | 1. Beam Optics - Can UITF deliver the beam HDIce needs | ||
2. Are there sufficient diagnostic devices to aid in beam delivery? | 2. Are there sufficient diagnostic devices to aid in beam delivery? |
Revision as of 16:34, 9 March 2016
Charge
Evaluate the UITF design with respect to beam requirements for HDIce.
1. Beam Optics - Can UITF deliver the beam HDIce needs 2. Are there sufficient diagnostic devices to aid in beam delivery? 3. Given the low CW beam current, what devices or what process can ensure that the beam is at the intended place on the target? 4. Given the sensitivity of HDIce target to > nA beam for any length of time (msecs), are there possible measures to protect the target?
Advance Material
*UITF Description *HDIce Beam Requirements *UITF mechanical layout *UITF Optics