== Opportunistic tests and long-term ideas off the top of my head ==
+
== Random ==
 
+
* Make sure we know which peak is which in the harp scans (make beam spot asymmetric and compare with viewer).
+
* Readjust buncher amplitude by minimizing p spread on 703?
+
* Measure p spread on 703
+
* Float gun-energy beam to 703 to verify MDLM601 calibration. Not sure if possible, but worth trying. Detune both cavities, use BPMs liberally.
+
* Have the intermittent RF instabilities fixed
+
* Measure how much juice the BPMs need for reliable positions, particularly in the keV region
+
* Is there anything we can learn from the BPMs / correctors to supplement the gun kick study at CEBAF?
+
* Implement QE tool per Joe's request. Got shopping list from Michele
+
* It would be nice to have an extra corrector before the booster to get a nicer axis through both cavities. Prefer the duct-tape variety to nothing at all
+
* Permanently incorporate prep chamber stuff into EPICS
+
** stalk heater PS, temperature readback, ion pump current, anode current. Consider protection logic to disable heater if pressure or temp gets too high. Add oven timer. It should automagically post a completion notice to UITFLOG.
+
** maybe also an EPICS-switchable DC voltage for the auxiliary laser diode (replaces manual "beam shutter")?
+
** have a second PS for the dispenser; could be remote-controlled or not, don't really care... we can't automate the whole process anyway because of the manual valve
+
 
+
== Preparation for HKDL ==
+
 
+
* The keV emittance can be measured at 501 provided intrinsic energy spread is negligible (buncher off).
+
* qsUtility lacks harps to directly measure the optical functions prior to M601, especially directly before and after the booster. Need to measure them at M601 for a few suitable beam energies and backpropagate to M401 in preparation for simulations of the HKDL optics.
+

Latest revision as of 17:04, 20 December 2021