Difference between revisions of "Template:ShortTermSchedule-RGD"
Jump to navigation
Jump to search
Line 120: | Line 120: | ||
** Once the access is done, please ask MCC for 35 nA and take 100 M triggers runs with LD2 until the end of the Swing shift with the same <tt>PROD66</tt> DAQ configuration and '''rgd_v1.0_no_DC.trg''' trigger file. | ** Once the access is done, please ask MCC for 35 nA and take 100 M triggers runs with LD2 until the end of the Swing shift with the same <tt>PROD66</tt> DAQ configuration and '''rgd_v1.0_no_DC.trg''' trigger file. | ||
** <font color=Brown>P.S.: Please check with Eugene when he could come to ramp down the torus and solenoid magnets as a preparation for the alignment run. </font><font color=blue><center>-----''If everything goes well, that should bring us to the OWl shift'' -----</font></center> | ** <font color=Brown>P.S.: Please check with Eugene when he could come to ramp down the torus and solenoid magnets as a preparation for the alignment run. </font><font color=blue><center>-----''If everything goes well, that should bring us to the OWl shift'' -----</font></center> | ||
− | ** Continue LD2 data-taking with 35 nA and 100 M triggers runs until the alignment run is taken. | + | ** Continue LD2 data-taking with 35 nA and 100 M triggers runs until the alignment run is ready to be taken. |
** Once ready for the alignment run, call Xiaodong or follow instructions to boil off LD2. | ** Once ready for the alignment run, call Xiaodong or follow instructions to boil off LD2. | ||
** Ask MCC for 1 nA, and take 10 M electron triggers run with zero-field and the following electron trigger file based on CTOFxCND coincidence with no-DC-roads: | ** Ask MCC for 1 nA, and take 10 M electron triggers run with zero-field and the following electron trigger file based on CTOFxCND coincidence with no-DC-roads: |
Revision as of 21:41, 21 September 2023
Run Coordinator: Lamiaa El Fassi (757) 575-7540
PDL: Nathan Baltzell (9-)757 876-1789 , x5902 office
RG/Analysis Coordinator (AC): Lamiaa El Fassi (630) 605-4259
Daily RC Meetings at 13:00 on CH Room 200C, and on ZOOM: URL Link (Meeting ID: 1611984219; Passcode: RGD-RC23), except on Wednesdays, which is in ZOOM ONLY @ 15:30 due to the conflict with the 13:30 MCC meeting.
Important Notes
- In case of medical or fire emergency, call 9-911 from a LANDLINE phone in the Counting House
- If you have symptoms or a positive COVID test, do NOT come to your shift - instead, inform the PDL and the RC and JLab medical services immediately to arrange replacements.
- Remote shift: If needed, worker shifts can be taken from off-site. Inform the PDL and RC. Also, make sure that you follow the instructions under the "Worker Shift" Tab - you need some lead time to set up!
Note to shift takers, please:
- Read the logbook, be aware of previous 24 hours
- Arrive at least 10 minutes early for shift change
- Refresh the run wiki pages; look over them every shift
- Follow the expert/worker shift instructions
- Communicate with your co-shift person
- The shift expert should know about and refer to logbook entries in their shift summary
- The shift worker should discuss an issue with the shift expert before making extra logbook entries
Run Plan for Sept. 29th to Oct. 2nd, 2023
DAQ configuration
Reference ValuesFSD Thresholds from RG-C (to-be-changed for RG-D)
Harp Scan References from RG-C (to-be-changed for RG-D) |
General Instructions:
Every Shift:
Every Run:
To access the Hall:
|