− | == Tuesday, | + | == Tuesday, April 2 == |
+ | * When the beam is back, start with beam tuning in the tagger dump: | ||
+ | ** ask MCC to energize the tagger magnet, | ||
+ | ** mask halo counters and BOM in FSD, and move the collimator to the "Blank" position, | ||
+ | ** ask for a 5 nA beam to the tagger dump, rates on upstream halo counters should be ~<1 kHz, | ||
+ | ** perform harp scans, 2C21 first, then the tagger_harp, and compare results with nominals (links are ported on the right side of this page). | ||
+ | ** If the beam profile and the position (standard deviation and the mean values of the Gaussian fits) are close to the previous tune, ask to take the beam away to prepare for the Moller run. Otherwise, work with MCC OPS to correct beam profiles and positions. | ||
+ | * Preparing for the Moller run: | ||
+ | ** take the beam away, open the Moller GUI, and follow instructions to configure the Moller polarimeter, | ||
+ | ** when ready, ask for a 20 nA beam and start the run. Make sure the ACC/Coinc ratio is <0.1, and the charge asymmetry is <0.2% | ||
+ | ** repeat the Moller run with with revered Helmholtz field. | ||
+ | * | ||
+ | |||
* Target: Yes | * Target: Yes | ||
* Beam Blocker: OUT | * Beam Blocker: OUT | ||
* Configuration: <tt>PROD67</tt> | * Configuration: <tt>PROD67</tt> | ||
− | In case of the need to manipulate the whole target system - cryotarget or solids - please contact | + | In case of the need to manipulate the whole target system - cryotarget or solids - please contact the target experts. |
LD2+Pb runs | LD2+Pb runs |
Revision as of 15:00, 1 April 2024
Run Coordinator: Hayk Hakobyan (757) 575-7540
PDL: Nathan Baltzell (757) 876-1789, Office: x5902
Important Notes
- In case of medical or fire emergency, call 9-911 from a LANDLINE phone in the Counting House and inform the Crew Chief and RC.
- In case of evacuation of the Counting Room (e.g., due to a fire alarm), grab the shift expert phone and leave the room through the "EXIT" door leading to the parking lot. Do not leave through the hallway! Call the RC once outside so the latter will call MCC to turn the beam OFF to Hall B and inform other Hall B staff members.
- If you have symptoms or a positive COVID test, do NOT come to your shift - instead, inform the PDL and the RC and JLab medical services immediately to arrange replacements.
Tuesday, April 2
In case of the need to manipulate the whole target system - cryotarget or solids - please contact the target experts. LD2+Pb runs
Information on triggers please see here: https://logbooks.jlab.org/entry/4267187
|
ReferencesBPM Positions
Harp ScansFSD ThresholdsDo NOT change FSD settings without approval from RC or beamline expert!
Charge Asymmetry |
General Reminders
|
DAQ Operation
|