* '''Thursday, Oct. 12th, Day Shift''': | * '''Thursday, Oct. 12th, Day Shift''': | ||
:• Depending on the status of the run during the changeover, please end the run once it reaches 100 M, then start the RICH threshold scans. | :• Depending on the status of the run during the changeover, please end the run once it reaches 100 M, then start the RICH threshold scans. | ||
− | :• Please ask MCC for 35 nA and take three 1h 30min runs with BEAM-ON and the following DAQ configuration: | + | :• Please ask MCC for 35 nA and take three 1h 30min runs with BEAM-ON and the following DAQ configuration and trigger files mentioned below: |
::- ''DAQ Config.'': <tt>PROD66_PIN</tt>. <font color=blue> Follow the DAQ instructions below to change its configurations and load new trigger files.</font> | ::- ''DAQ Config.'': <tt>PROD66_PIN</tt>. <font color=blue> Follow the DAQ instructions below to change its configurations and load new trigger files.</font> | ||
− | ::- '' | + | ::- Load the ''trigger file'': '''rgd_v1.0_no_DC_RICH_50.trg''' for the first 1h 30min BEAM-ON run, |
− | + | ::- Load the ''trigger file'': '''rgd_v1.0_no_DC_RICH_100.trg'''for the second 1h 30min BEAM-ON run, | |
− | ::- | + | ::- Load the ''trigger file'': '''rgd_v1.0_no_DC_RICH_200.trg'''for the third 1h 30min BEAM-ON run. |
− | ::- | + | :• '''P.S.: While approaching the end of the 3rd run (''at least 1/2h before its end''), please contact the SVT/MVT experts, Yuri and Rafo, to check the HV setting of MVT in the next Lumi. scans runs. Also, please keep an eye on the DC occupancy on mon12 and refresh it frequently during the Lumi. scan. |
− | ::- | + | ::‡ Ask MCC for 20 nA and take a 10 M triggers run with the following trigger file: |
+ | :::- ''Trigger file'': '''rgd_v1.0_no_DC_20nA.trg'''. <font color=blue> Follow the DAQ instructions below to load a new trigger file</font>. | ||
+ | ::‡ Ask MCC for 55 nA and take a 25 M triggers run with the following trigger file: | ||
+ | :::- ''Trigger file'': '''rgd_v1.0_no_DC_50nA.trg'''. <font color=blue> Follow the DAQ instructions below to load a new trigger file</font>. | ||
+ | ::‡ Ask MCC for 75 nA and take a 25 M triggers run with the following trigger file: | ||
+ | :::- ''Trigger file'': '''rgd_v1.0_no_DC_90nA.trg'''. <font color=blue> Follow the DAQ instructions below to load a new trigger file</font>. | ||
+ | :• Once done, continue the LD2 outbending production with 50 nA and 100 M runs by using the following configuration: | ||
+ | ::- ''DAQ Config.'': <tt>PROD66</tt>. <font color=blue> Follow the DAQ instructions below to change its configurations and load new trigger files.</font> | ||
+ | ::- ''Trigger file'': '''rgd_v1.0_no_DC.trg'''. <font color=blue><center>-----''If everything goes well, that should bring us to the Owl shift''----</font> | ||
+ | * '''Thursday, Oct. 12th, Swing Shift''': | ||
+ | :• Continue the LD2 outbending production with 50 nA and 100 M runs by using the following configuration: | ||
+ | ::- ''DAQ Config.'': <tt>PROD66</tt>. <font color=blue> Follow the DAQ instructions below to change its configurations and load new trigger files.</font> | ||
+ | ::- ''Trigger file'': '''rgd_v1.0_no_DC.trg'''. <font color=blue><center>-----''If everything goes well, that should bring us to the Owl shift''----</font> | ||
* '''Friday, Oct. 13th, Owl Shift''': | * '''Friday, Oct. 13th, Owl Shift''': | ||
:• Continue LD2 outbending production with 50 nA by taking 100 M runs with the following configuration: | :• Continue LD2 outbending production with 50 nA by taking 100 M runs with the following configuration: |
Revision as of 20:01, 11 October 2023
Run Coordinator: Susan Schadmand (757) 575-7540
PDL: Nathan Baltzell (9-)757 876-1789 , x5902 office
RG/Analysis Coordinator (AC): Lamiaa El Fassi (630) 605-4259
Daily RC Meetings at 13:00 in CH Room 200C, and on ZOOM: URL Link (Meeting ID: 1611984219; Passcode: RGD-RC23), except on Wednesdays, which is on ZOOM ONLY @ 15:30 due to the conflict with the 13:30 MCC meeting.
Important Notes
- In case of medical or fire emergency, call 9-911 from a LANDLINE phone in the Counting House
- If you have symptoms or a positive COVID test, do NOT come to your shift - instead, inform the PDL and the RC and JLab medical services immediately to arrange replacements.
- Remote shift: If needed, worker shifts can be taken from off-site. Inform the PDL and RC. Also, make sure that you follow the instructions under the "Worker Shift" Tab - you need some lead time to set up!
- Note to shift takers, please:
- ◊ Read the logbook, be aware of previous 24 hours
- ◊ Arrive at least 10 minutes early for shift change
- ◊ Refresh the run wiki pages; look over them every shift
- - Follow the expert/worker shift instructions
- ◊ Communicate with your co-shift person
- - The shift expert should know about and refer to logbook entries in their shift summary
- - The shift worker should discuss an issue with the shift expert before making extra logbook entries
- ◊ For advice, do not hesitate to call the RC first and foremost, day and night.
- ◊ For the required controlled access to change the LD2 and solid targets position down in the hall, please refer to this logbook entry #: 419613 for its requirement.
- ◊ Do NOT change FSD settings without approval from RC or beamline expert!
Run Plan for Oct. 11th to Oct. 13th, 2023
. DAQ configuration
Reference ValuesFSD Thresholds from RG-D
Harp Scan References from RG-D
IA for Q Asymmetry |
General Instructions:
Every Shift:
Every Run:
To access the Hall:
|