Difference between revisions of "Template:ShortTermSchedule-RGK"
Jump to navigation
Jump to search
Line 6: | Line 6: | ||
''' [https://clasweb.jlab.org/wiki/index.php/Run_Group_K#tab=Daily_RC/OA_Meetings Daily RC/OA Meetings] at 13:00 in CH Room 200C, and on ZOOM: [https://urldefense.proofpoint.com/v2/url?u=https-3A__jlab-2Dorg.zoomgov.com_s_1613823885&d=DwMFaQ&c=CJqEzB1piLOyyvZjb8YUQw&r=eD2eIWJtzd_0pBXdk6zLEQ&m=aITu0ps9wU_2NIx5HWL0fnCywIAlGV0rhQoEhp3s1SpX6aR3xJ7qrKmdAOhEGyOX&s=ZIcygrMxBgoKIomLBse777fTFeTQobKD2awZ-LaTP1w&e= URL Link] | ''' [https://clasweb.jlab.org/wiki/index.php/Run_Group_K#tab=Daily_RC/OA_Meetings Daily RC/OA Meetings] at 13:00 in CH Room 200C, and on ZOOM: [https://urldefense.proofpoint.com/v2/url?u=https-3A__jlab-2Dorg.zoomgov.com_s_1613823885&d=DwMFaQ&c=CJqEzB1piLOyyvZjb8YUQw&r=eD2eIWJtzd_0pBXdk6zLEQ&m=aITu0ps9wU_2NIx5HWL0fnCywIAlGV0rhQoEhp3s1SpX6aR3xJ7qrKmdAOhEGyOX&s=ZIcygrMxBgoKIomLBse777fTFeTQobKD2awZ-LaTP1w&e= URL Link] | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
== '''Important Notes''' == | == '''Important Notes''' == | ||
:::::::::::::::<span style="font-size:122%; line-height: 2em;"><p class="animate flash"><font color=red>''' Do NOT change FSD settings without approval from RC or beamline expert!'''</font></p></span> | :::::::::::::::<span style="font-size:122%; line-height: 2em;"><p class="animate flash"><font color=red>''' Do NOT change FSD settings without approval from RC or beamline expert!'''</font></p></span> | ||
+ | |||
+ | * <font color="red"> The BPM 2H01 needs time for the temperature to stabilize before it can be tuned. Until it is tuned, its value and the beam orbit lock which relies on it, will not be valid. The orbit lock should remain '''OFF''' until the BPM is tuned, expected Fri. Jan 12 AM.</font> | ||
* '''In case of medical or fire emergency, call 9-911 from a LANDLINE phone in the Counting House''' and inform the Crew Chief and RC. | * '''In case of medical or fire emergency, call 9-911 from a LANDLINE phone in the Counting House''' and inform the Crew Chief and RC. | ||
Line 109: | Line 100: | ||
* '''Beamline''': | * '''Beamline''': | ||
− | ** Do not run over 30 minutes above <font color=fuchsia> XX </font> nA | + | ** Do not run over 30 minutes above <font color=fuchsia> XX </font> nA with a 3rd pass beam without the <b> beam blocker IN </b>. |
** If there is any concern about beam stability, ask MCC if orbit locks are on (they should be). | ** If there is any concern about beam stability, ask MCC if orbit locks are on (they should be). | ||
** Document any beam condition change and send scaler GUIs to HBLOG. | ** Document any beam condition change and send scaler GUIs to HBLOG. | ||
** If HWP is changed, start a new run | ** If HWP is changed, start a new run | ||
− | *** | + | *** The absolute values <font color=fuchsia> of the SLM and FCUP charge asymmetry (Q-Asym (%)) </font> should be less than 0.1%. |
* For '''beam tuning and Møller runs''' | * For '''beam tuning and Møller runs''' | ||
** Make sure the SVT/MVT are set as follows: '''SVT: LV ON; HV OFF''', and '''MVT: LV ON; HV ON - Safe Voltage''' | ** Make sure the SVT/MVT are set as follows: '''SVT: LV ON; HV OFF''', and '''MVT: LV ON; HV ON - Safe Voltage''' | ||
*** From HV->Overview->Actions, '''select BMT HV ON - Safe Voltage'''. <font color=fuchsia> The command also selects FMT HV ON - Safe Voltage. </font> | *** From HV->Overview->Actions, '''select BMT HV ON - Safe Voltage'''. <font color=fuchsia> The command also selects FMT HV ON - Safe Voltage. </font> | ||
− | *** | + | *** For Production/Calibration/Various-Studies, select BMT (/FMT) "HV ON - Full Voltage".</font> |
− | |||
** Turn <b> DC HV </b> off only for beam tuning; if no beam is available or when the beam is stable, keep them on even if you are not taking data. | ** Turn <b> DC HV </b> off only for beam tuning; if no beam is available or when the beam is stable, keep them on even if you are not taking data. | ||
Line 140: | Line 130: | ||
:- "Go" | :- "Go" | ||
− | * '''Restart DAQ | + | * '''Restart DAQ''' when changing configuration or trigger files, when the run did not end correctly, when ROCs are rebooted, or after RICH Fast/Full recovery: |
:- "Cancel" | :- "Cancel" | ||
:- "Reset" | :- "Reset" | ||
Line 179: | Line 169: | ||
* Tagger (2C24A) [https://logbooks.jlab.org/entry/4234737]: x= -2.0 mm; y= +0.6 mm | * Tagger (2C24A) [https://logbooks.jlab.org/entry/4234737]: x= -2.0 mm; y= +0.6 mm | ||
* 2H01 [https://logbooks.jlab.org/entry/4234764]; x= -1.4 mm; y= 0.0 mm | * 2H01 [https://logbooks.jlab.org/entry/4234764]; x= -1.4 mm; y= 0.0 mm | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− |
Revision as of 09:44, 11 January 2024
Experiment Coordinator: Annalisa D'Angelo
Run Coordinator: Axel Schmidt (757) 575-7540
PDL: Daniel Carman (757) 876-1789; Office: x5586
Daily RC/OA Meetings at 13:00 in CH Room 200C, and on ZOOM: URL Link
Important Notes
Do NOT change FSD settings without approval from RC or beamline expert!
- The BPM 2H01 needs time for the temperature to stabilize before it can be tuned. Until it is tuned, its value and the beam orbit lock which relies on it, will not be valid. The orbit lock should remain OFF until the BPM is tuned, expected Fri. Jan 12 AM.
- In case of medical or fire emergency, call 9-911 from a LANDLINE phone in the Counting House and inform the Crew Chief and RC.
- In case of evacuation of the Counting Room (e.g., due to a fire alarm), grab the shift expert phone and leave the room through the "EXIT" door leading to the parking lot. Do not leave through the hallway! Call the RC once outside so the latter will call MCC to turn the beam OFF to Hall B and inform other Hall B staff members.
- If you have symptoms or a positive COVID test, do NOT come to your shift - instead, inform the PDL and the RC and JLab medical services immediately to arrange replacements.
- Remote shift: If needed, worker shifts can be taken from off-site. Inform the PDL and RC. Also, make sure that you follow the instructions under the "Shift Worker" tab, as you need some lead time to set up!
- Note to Shift Takers:
- Read the ESAD, COO, RSAD, and ERG documents found on the "Current RG-K Run Info" as well as the yellow folder in the counting room. Before you start your first shift on the current experiment, you must sign on the list in the yellow folder. Thereby, you confirm that you have read and understand their content.
- Read at least the previous 24 hours logbook entries to be aware of recent run details and changes;
- Arrive at least 10 minutes early for shift change;
- Refresh the runwiki page/tabs; look over it/them every shift:
- Follow the Shift Expert/Worker tab's instructions.
- Do not spend more than 15-20 min trying to fix a problem. In case of any issue, contact the On-call Experts or the RC.
- Important links
- Recent Changes and Current Issues Needs updating
- General How-to for beam restoration procedures and Møller runs.
Run Plan, Thursday, Jan. 11 - Saturday, Jan. 13, 2024
|
General Information
|
DAQ Operation & Related General Information
|
|
Reference Values
FSD Thresholds from RG-K
- Upstream: 2 kHz
- Midstream: 2 kHz
- Downstream: 100 kHz
- BOM: 50 kHz
- 5 ms dwell time