Daily RC Meetings at 13:00 in CH Room 200C, and on ZOOM: URL Link (Meeting ID: 1611984219; Passcode: RGD-RC23), except on Wednesdays, which is on ZOOM ONLY @ 15:30.
Do NOT change FSD settings without approval from RC or beamline expert!
Line 9: | Line 9: | ||
<center><font color=red>''' Do NOT change FSD settings without approval from RC or beamline expert!'''</font></center> | <center><font color=red>''' Do NOT change FSD settings without approval from RC or beamline expert!'''</font></center> | ||
− | * | + | * In case of medical or fire emergency, call 9-911 from a LANDLINE phone in the Counting House and inform the Crew Chief and RC. |
− | * | + | * In case of evacuation of the Counting Room (e.g., due to a ''fire alarm''), grab the shift expert phone and leave the room through the "<font color=red>EXIT</font>" door leading to the parking lot. Do not leave through the hallway! Call the RC once outside so the latter will call MCC to turn the beam OFF to Hall B and inform other Hall B staff members. |
− | * If you have symptoms or a positive | + | * If you have symptoms or a positive COVID test, do NOT come to your shift - instead, inform the PDL and the RC and JLab medical services immediately to arrange replacements. |
{| {{TableStyle1}} | {| {{TableStyle1}} | ||
Line 17: | Line 17: | ||
| valign=top width=50% | | | valign=top width=50% | | ||
− | == | + | == Monday, March 10 - Monday, Dec. 4 == |
* Continue CuSn data-taking as follows: | * Continue CuSn data-taking as follows: | ||
− | :- Target: | + | :- Target: CuSn |
− | :- Beam Blocker: | + | :- Beam Blocker: IN |
| valign=top | | | valign=top | | ||
− | == | + | == General Instructions == |
* The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights are being kept off because of light leaks affecting some of the detectors (especially ECAL sec 2 and 3). If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''. | * The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights are being kept off because of light leaks affecting some of the detectors (especially ECAL sec 2 and 3). If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''. | ||
Line 32: | Line 32: | ||
** Note that when the dome lights are switched off, they cannot be turned back on immediately because they require 10-15 min to cool down. | ** Note that when the dome lights are switched off, they cannot be turned back on immediately because they require 10-15 min to cool down. | ||
− | * | + | * Beamline: |
− | + | ** '''Do not run over XX minutes above YY nA with a 5-pass beam without the <b> beam blocker IN.''' The beam blocker must be IN for long-running at high currents for 5-pass operations. | |
− | + | ** If there is any concern about beam stability, ask MCC if orbit locks are on (they should be). | |
− | + | ** Document any beam condition change and send scaler GUIs to HBLOG. | |
− | + | ** If HWP is changed, start a new run. | |
− | * For | + | * For beam tuning and Møller runs |
:• Make sure the SVT/MVT are set as follows: '''SVT: LV ON; HV OFF''', and '''MVT: LV ON; HV ON in SAFE Mode.''' | :• Make sure the SVT/MVT are set as follows: '''SVT: LV ON; HV OFF''', and '''MVT: LV ON; HV ON in SAFE Mode.''' | ||
::- When '''turning MVT OFF''', do not press "BMT HV OFF" from HV->Overview->Actions, but instead '''select BMT HV ON - Safe Voltage'''. The same applies to FMT '''select FMT HV ON - Safe Voltage'''. | ::- When '''turning MVT OFF''', do not press "BMT HV OFF" from HV->Overview->Actions, but instead '''select BMT HV ON - Safe Voltage'''. The same applies to FMT '''select FMT HV ON - Safe Voltage'''. |
Revision as of 12:00, 26 February 2024
Run Coordinator: Hayk Hakyoban (757) 575-7540
PDL: Nathan Baltzell (9-) 757 876-1789; Office: x5902
Important Notes
- In case of medical or fire emergency, call 9-911 from a LANDLINE phone in the Counting House and inform the Crew Chief and RC.
- In case of evacuation of the Counting Room (e.g., due to a fire alarm), grab the shift expert phone and leave the room through the "EXIT" door leading to the parking lot. Do not leave through the hallway! Call the RC once outside so the latter will call MCC to turn the beam OFF to Hall B and inform other Hall B staff members.
- If you have symptoms or a positive COVID test, do NOT come to your shift - instead, inform the PDL and the RC and JLab medical services immediately to arrange replacements.
Monday, March 10 - Monday, Dec. 4
|
General Instructions
|
|
|
Reference Values
FSD Thresholds from RG-D
- Upstream: 2 kHz
- Midstream: 2 kHz
- Downstream: 100 kHz
- BOM: 50 kHz
- 5 ms dwell time
Harp Scan References from RG-D
- 2H01 [3]; x= -1.4 mm; y= 0.0 mm
- Tagger (2C24A) [4]: x= -2.0 mm; y= +0.6 mm
- 2C21A [5]: x= -0.4 mm; y= +0.6 mm (less important; values form RG-C)