Conference Call with AL/S2M 24 Jan 17
From Cryowiki
JLAB Attendance
Creel, Wright, Arenius
Al/S2M Attendance
Panchali, Emmanual
Agenda and Notes
1. Initial Findings
Air Liquid and S2M reported the axis of the three flat spots where the wheel mounts are no longer aligned with the axis of the main shaft.
2. Discussion
AL/S2M stated they believe the problem did not arise from the sputtering and machine work but they did not take complete measurements before the work was performed so they cant say for certain.
3. Decision
It was decided to allow both parties to consider the information and try to brainstorm options from this point. Another meeting will be set for one week from today.
Action Item Updates
1.