1. Inspection of the yoke components and dimensions. 2. Inspection of the main and corrector coils. 3. Assembly of the magnet with coils. Installation of the water cooling and temperature control items. Installation of safety signs. 4. Test of the electrical parameters (resistance and leak current). Measurement of teh water flow at design pressure drop. 5. Test of the magnet operation at 10% power. 6. Test of the main coil at full current of 990 A and voltage 110 V across the main coil (see more in the SAM_main_coil_specifications.pdf). 7. Test of the corrector coils at full current of 520 A and voltage drop 20 V (each coil) (see more in the SAM_corr_coil_specifications.pdf). 8. Field mapping along the beam line for 6.3 degree case, 10 degree case. Compare results with expectation per 9. Field mapping in the main gap with 5-10 cm grid 10. Field mapping in location of the NPS calorimeter.