Difference between revisions of "General Meeting Summary 3/28/13"
Jump to navigation
Jump to search
(2 intermediate revisions by the same user not shown) | |||
Line 12: | Line 12: | ||
::* So for a point target, the minimum angle is 58 mr or 3.4 degrees. For an extended target you will need to adjust, it becomes about 4 degree for a 15 cm target. So assume 3.5 degrees as rough number. | ::* So for a point target, the minimum angle is 58 mr or 3.4 degrees. For an extended target you will need to adjust, it becomes about 4 degree for a 15 cm target. So assume 3.5 degrees as rough number. | ||
− | * Discussion on degradation of crystals (see Hamlet's presentation from January) | + | * Discussion on degradation of crystals (see [http://www.vsl.cua.edu/cua_phy/images/c/cb/Hamlet.pdf Hamlet's presentation from January]) |
Line 26: | Line 26: | ||
* WACS is planning to circulate draft proposal for collaboration sign up around 20 April. | * WACS is planning to circulate draft proposal for collaboration sign up around 20 April. | ||
− | * Some discussion on the core list of collaborators for each proposal (perhaps good start is collaborators listed on Wiki?) | + | * Some discussion on the core list of collaborators for each proposal (perhaps good start is [[https://wiki.jlab.org/cuawiki/index.php/List_of_Participants the list of collaborators]] listed on Wiki?) |
− | * Decided on LaTeX as official language for proposal writing | + | * Decided on LaTeX as ''official'' :-) language for proposal writing |
Latest revision as of 12:44, 29 March 2013
BACKGROUND STUDIES/DETECTOR
- Exclusive experiments require the small beam pipe assembly allowing HMS to reach angles >=10.5 degrees. Though there may be solutions for kinematics with >=13 degrees these could only be achieved at the cost of changing kinematics and reducing the range of lever arm in Q^2. Thus dropping these smaller angles would lead to an important loss of physics.
- From WACS point of view a bigger beam pipe could be preferable depending on the relative contribution of backgrounds from target and beam pipe components.
- Scattering Chamber information:
- outer diameter = 45 inches
- inner diameter = 43.125 inches
- distance beam line to SHMS window = 1.25 inches
- So for a point target, the minimum angle is 58 mr or 3.4 degrees. For an extended target you will need to adjust, it becomes about 4 degree for a 15 cm target. So assume 3.5 degrees as rough number.
- Discussion on degradation of crystals (see Hamlet's presentation from January)
DVCS/MESON KINEMATICS
- Review and finalize kinematics table. Special meeting set up for Tuesday 2 April.
PROPOSAL PREPARATION
- Proposal submission due date is Monday, 6 May, at 8 AM.
- WACS is planning to circulate draft proposal for collaboration sign up around 20 April.
- Some discussion on the core list of collaborators for each proposal (perhaps good start is [the list of collaborators] listed on Wiki?)
- Decided on LaTeX as official :-) language for proposal writing
ITEMS FOR NEXT MEETING:
- Evaluate the fraction of background from target vs. beam line components.
- DVCS/meson final kinematics
- Based on previous proposal(s) prepare list of requests for information on technical aspects of the detector, e.g., paragraphs, figures etc. needed for the proposal instrumentation section
NEXT MEETING: THUR, 4 APRIL at 9AM (EST)