Difference between revisions of "Documents"
Line 34: | Line 34: | ||
== Detector == | == Detector == | ||
− | * PMT specs: Hamamatsu R4125, 19mm diameter, gain is about 8.7E+5 at 1.5kV max. anode voltage and rise time 2.5ns. This PMT was also used in Primex and we have designed a new active voltage divider that improves the performance of the PMT by a factor of 25. See the report at the 2012 IEEE NSS/MIC/RTSD conference by V. Popov and H. Mkrtchyan. | + | * ''PMT specs'': Hamamatsu R4125, 19mm diameter, gain is about 8.7E+5 at 1.5kV max. anode voltage and rise time 2.5ns. This PMT was also used in Primex and we have designed a new active voltage divider that improves the performance of the PMT by a factor of 25. See the report at the 2012 IEEE NSS/MIC/RTSD conference by V. Popov and H. Mkrtchyan. |
− | * PbWO4 references: | + | * ''PbWO4 references'': |
::* P. Adzic et al., "Radiation Hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter", CMS Note 2009/016 | ::* P. Adzic et al., "Radiation Hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter", CMS Note 2009/016 | ||
::* A.A. Annenkov et al., "Lead Tungstate scintillation material", NIM A 490 (2002) 30-50 | ::* A.A. Annenkov et al., "Lead Tungstate scintillation material", NIM A 490 (2002) 30-50 |
Revision as of 13:45, 22 August 2013
PAC40
Physics
DVCS
Rafael's first report on DVCS simulations
Charles presentation from Hall C meeting, 24 January 2013
Study of effects on kinematics if require HMS angle to be >=13 deg (.pdf)
Beam Time Sharing DVCS and pi0 (.pdf)
WACS
Simon's report on WACS simulations
Notes from Peter Kroll, Nov 2012
SIDIS mesons
DES mesons
Notes from Peter Kroll, Nov 2012
Detector
- PMT specs: Hamamatsu R4125, 19mm diameter, gain is about 8.7E+5 at 1.5kV max. anode voltage and rise time 2.5ns. This PMT was also used in Primex and we have designed a new active voltage divider that improves the performance of the PMT by a factor of 25. See the report at the 2012 IEEE NSS/MIC/RTSD conference by V. Popov and H. Mkrtchyan.
- PbWO4 references:
- P. Adzic et al., "Radiation Hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter", CMS Note 2009/016
- A.A. Annenkov et al., "Lead Tungstate scintillation material", NIM A 490 (2002) 30-50
- P. Yang et al., "Growth of large-size crystal of PbWO4 by vertical Brigdman method with multi-crucibles
- R. W. Novotny, "The Electromagnetic Calorimetry of the PANDA Detector at FAIR", J. Phys. Conf. Serv. 404 012063 (2012)
Dose rate estimations for PbWO4 detector at 4m from target, at 1uA, and for a 10-cm long target
Scattering Chamber Information:
- outer diameter = 45 inches
- inner diameter = 43.125 inches
- distance beam line to SHMS window = 1.25 inches
So for a point target, the minimum angle is 58 mr or 3.4 degrees. For an extended target you will need to adjust, it becomes about 4 degree for a 15 cm target. So assume 3.5 degrees as rough number.
Study of possibilities for larger beam pipe assemblies
Energy spectra for electrons, photons, positrons including fits
Rates and rates per crystal vs. angle relative to beam for: 4 m from target, 6.6 GeV beam energy, 1uA beam current, and 10-cm LH2 target for:
Hamlet's report on crystal properties from Hall C meeting, 24 January 2013
New Active PMT Base for PbWO4 (Popov, H. Mkrtchyan, presentation at IEEE, Nov 2012)
Description of the PbWO4 detector option: