Difference between revisions of "General Meeting Summary 10/31/19"
Jump to navigation
Jump to search
(Created page with "MAGNET * ODU mapping tests ongoing HV DIVIDERS * All dividers are assembled at Ohio U! ::* 2/3 of the dividers have been tested *") |
|||
Line 9: | Line 9: | ||
::* 2/3 of the dividers have been tested | ::* 2/3 of the dividers have been tested | ||
− | * | + | * Discussion about divider non-linearity and impact on physics |
+ | ::* Level of non-linearity should be less than calorimeter resolution, e.g. if ~<1% non-linearity, then should not affect resolution | ||
+ | ::* Based on prototype beam tests, the bypassed version of the amplifier gives the expected resolution | ||
+ | ::::* design acceptable since resolution ~1% | ||
+ | ::::* will have effect on positioning, but an be corrected offline - more important is that the PMT survives (anode current ~<100ua) | ||
+ | ::* How well can non-linearity be measured? - if known well enough then an always correct | ||
+ | |||
+ | * Discussion about three new (reduced gain) divider designs recently made by V. Popov | ||
+ | ::* Test with LED - find average current of PMT, need to know anode current of PMT | ||
+ | ::* Take same PMT and check different types of dividers, e.g. bypassed vs. reduced gain, any improvements? | ||
+ | |||
+ | * Action Item: Collect information for all existing dividers | ||
+ | ::* resolution | ||
+ | ::* non-linearity | ||
+ | |||
+ | |||
+ | FRAME - MAGNETIC SHIELDING STUDY | ||
+ | |||
+ | * Comparing PMT specs and field map suggests that with shielding the field is 50G (transverse) and ~100G (longitudinal), so a significant effect --> must pay attention to shielding | ||
+ | ::* current shielding: 1mm mu metal around PMT | ||
+ | ::* consider adding soft iron and perhaps additional mu metal around entire box including crystals | ||
+ | |||
+ | * Discussion of mechanical aspects of adding shielding around the box | ||
+ | ::* distance front plate to PMT is 20.3cm - adding shielding should be fine | ||
+ | ::* back of box - adding shielding is difficult due to cables, high voltage, etc. Can add an incomplete shielding coverage on the back | ||
+ | |||
+ | * Discussion of predicting the impact of (additional) shielding on overall magnetic field where the PMTs are | ||
+ | ::* Rough estimate of magnetic shielding needed: | ||
+ | ::::* Transverse size of the box is 60cm (30 crystals at 20cm each) | ||
+ | ::::* Typical PMT shielding expectation is to extend shielding by 1 radius of the photocathode (here use the transverse size of the box) | ||
+ | ::* Once decide where all shielding is located (geometry) can do a numerical calculation | ||
+ | ::* Based on numerical calculation can also determine if need additional front shielding | ||
+ | ::* |
Revision as of 14:19, 1 November 2019
MAGNET
- ODU mapping tests ongoing
HV DIVIDERS
- All dividers are assembled at Ohio U!
- 2/3 of the dividers have been tested
- Discussion about divider non-linearity and impact on physics
- Level of non-linearity should be less than calorimeter resolution, e.g. if ~<1% non-linearity, then should not affect resolution
- Based on prototype beam tests, the bypassed version of the amplifier gives the expected resolution
- design acceptable since resolution ~1%
- will have effect on positioning, but an be corrected offline - more important is that the PMT survives (anode current ~<100ua)
- How well can non-linearity be measured? - if known well enough then an always correct
- Discussion about three new (reduced gain) divider designs recently made by V. Popov
- Test with LED - find average current of PMT, need to know anode current of PMT
- Take same PMT and check different types of dividers, e.g. bypassed vs. reduced gain, any improvements?
- Action Item: Collect information for all existing dividers
- resolution
- non-linearity
FRAME - MAGNETIC SHIELDING STUDY
- Comparing PMT specs and field map suggests that with shielding the field is 50G (transverse) and ~100G (longitudinal), so a significant effect --> must pay attention to shielding
- current shielding: 1mm mu metal around PMT
- consider adding soft iron and perhaps additional mu metal around entire box including crystals
- Discussion of mechanical aspects of adding shielding around the box
- distance front plate to PMT is 20.3cm - adding shielding should be fine
- back of box - adding shielding is difficult due to cables, high voltage, etc. Can add an incomplete shielding coverage on the back
- Discussion of predicting the impact of (additional) shielding on overall magnetic field where the PMTs are
- Rough estimate of magnetic shielding needed:
- Transverse size of the box is 60cm (30 crystals at 20cm each)
- Typical PMT shielding expectation is to extend shielding by 1 radius of the photocathode (here use the transverse size of the box)
- Once decide where all shielding is located (geometry) can do a numerical calculation
- Based on numerical calculation can also determine if need additional front shielding