Difference between revisions of "General Meeting Summary 11/12/15"
Jump to navigation
Jump to search
(Created page with "Quick summary - to be updated CRYSTAL TESTING 2015/16 * Discussion about available facilities ::* IPN-Orsay: Transmittance (L&T, Varian Cary 4000), irradiation with source, ...") |
|||
Line 1: | Line 1: | ||
− | + | CRYSTAL TESTING FACILITIES | |
− | |||
− | CRYSTAL TESTING | ||
* Discussion about available facilities | * Discussion about available facilities | ||
− | ::* IPN-Orsay: Transmittance (L&T, Varian Cary | + | ::* IPN-Orsay: Transmittance (L&T, Ocean Optics fiber-based spectrometer with support structure, Varian Cary 5000), irradiation with source (Co-60, pointlike, 30Gy in 30 min), Light Yield with cosmics |
− | ::* Giessen Univ: Transmittance (L&T, Varian Cary 5000), Irradiation with source (Co-60, uniform), Light Yield with source ( | + | ::* Giessen Univ: Transmittance (L&T, Varian Cary 5000, reproducibility ~0.1%), Irradiation with source (Co-60, uniform, 30 Gy in 10 min, room temperature), Light Yield with source (temperature control to 0.1 deg) |
− | ::* CUA/CU: Transmittance (L&T, Perkin-Elmer Lambda 750), irradiation option with Xrays, Light Yield with Na-22 source (temperature stabilization better than 1 degree) | + | ::* CUA/CU: Transmittance (L&T, Perkin-Elmer Lambda 750, reproducibility ~0.2%), irradiation option with Xrays (Faxitron CP-160, energy range up to 160 kV), Light Yield with Na-22 source (temperature stabilization better than 1 degree) |
− | ::* Caltech: Transmittance (L&T, Perkin-Elmer Lambda 950), irradiation with source (Co-60, Cs-137 - pointlike?), Light Yield with source | + | ::* Caltech: Transmittance (L&T, Perkin-Elmer Lambda 950, reproducibility ~0.2%), irradiation with source (Co-60 for 2-30 rad/hr, Cs-137 for ~7000 rad/hr - sources pointlike?), Light Yield with Cs-137 source (systematic uncertainty 1%) |
− | ::* JLab: Transmittance (L&T, integrating sphere), prototype | + | ::* JLab: Transmittance (L&T, integrating sphere, reproducibility few %), prototype tests (light monitoring and recovery, temperature controlled frame, energy resolution), fADC-based readout and triggering |
* Discussion about crystal selection and testing sequence at different institutions | * Discussion about crystal selection and testing sequence at different institutions | ||
Line 17: | Line 15: | ||
− | MAGNET | + | CRYSTALS AT THE DIFFERENT INSTITUTIONS |
+ | |||
+ | * IPN-Orsay has BTCP crystals for testing optical and irradiation setup. Ordered 3 CRYTUR crystals and expecting them in January 2016 | ||
+ | |||
+ | * CUA has BTCP crystals for testing optical and irradiation setup. Also has one 10-cm long CRYTUR crystal (from Rainer) and one 2x2x2 PbF2 cube from SICCAS (through VSL) | ||
+ | |||
+ | * JLab has 11 SICCAS crystals from 2014 (9 are installed in the prototype, #1 and #4 are available for testing). Also has 30 SICCAS crystals from 2015, which have not yet been tested | ||
+ | |||
+ | * Caltech has 2 crystals from the SICCAS 2014 set (#5 and #11). Plans to do proton irradiation tests at Los Alamos with crystal #11 over next few months | ||
+ | |||
+ | * BNL has 2 crystals from the SICCAS 2014 set (#7 and #15). Plans to have these crystals tested at Caltech before returning | ||
+ | |||
+ | |||
+ | CRYSTAL TEST PLAN | ||
+ | |||
+ | * Select subset of crystals from both 2014 and 2015 by next NPS meeting (December 2015) | ||
+ | |||
+ | * Send crystals to one facility for testing | ||
+ | |||
+ | * Once tests are done send crystals to the next facility. Need to check on logistics for sending crystals to Europe. | ||
+ | |||
+ | |||
+ | CRYSTALS AND EIC | ||
+ | |||
+ | * Discussion about using PbWO4 crystals for the EIC endcap calorimeter and reconfiguring the NPS for that purpose | ||
+ | |||
+ | * Action item: GEMC of crystal matrix (~1000 crystals of dimensions 2x2x20 cm^3) in EIC detector environment | ||
+ | |||
+ | |||
+ | NPS MAGNET | ||
+ | |||
+ | * Discussion about two possible options for NPS magnet steel: parts of existing magnets, e.g., 45D45, or parts from the SBS counterweight | ||
+ | ::* Additional steel for WACS experiments could be procured through UK funds | ||
+ | |||
+ | * 3D magnet model has been sent to the designer | ||
+ | |||
+ | |||
+ | COLLABORATION MEETING: 21 JANUARY AT JLAB (time: TBD) | ||
+ | |||
+ | * General agenda topics as discussed previously include: | ||
+ | ::* existing thoughts to make the best optimal photon source needed for the approved polarized WACS experiment, but perhaps also beneficial for other already approved proposals | ||
+ | ::* updates on the progress with crystal tests/selection procedures | ||
+ | ::* update on magnet design | ||
+ | ::* update on PMT HV divider | ||
+ | ::* possibiliites for Timelike-Compton Scattering measurements with photon beam, NPS and polarized target in Hall C | ||
+ | ::* ... | ||
+ | |||
+ | |||
+ | ITEMS FOR NEXT MEETING: | ||
+ | |||
+ | * Background simulations | ||
+ | |||
+ | * Plan for crystal testing 2015/16+ | ||
+ | |||
+ | * Update on magnet | ||
+ | |||
+ | * Readout | ||
+ | |||
+ | * NPS collaboration meeting planning | ||
− | * | + | * Other... |
− | + | NEXT MEETING: THUR 10 DECEMBER, TIME: 9:00 AM (EST) |
Latest revision as of 12:59, 17 November 2015
CRYSTAL TESTING FACILITIES
- Discussion about available facilities
- IPN-Orsay: Transmittance (L&T, Ocean Optics fiber-based spectrometer with support structure, Varian Cary 5000), irradiation with source (Co-60, pointlike, 30Gy in 30 min), Light Yield with cosmics
- Giessen Univ: Transmittance (L&T, Varian Cary 5000, reproducibility ~0.1%), Irradiation with source (Co-60, uniform, 30 Gy in 10 min, room temperature), Light Yield with source (temperature control to 0.1 deg)
- CUA/CU: Transmittance (L&T, Perkin-Elmer Lambda 750, reproducibility ~0.2%), irradiation option with Xrays (Faxitron CP-160, energy range up to 160 kV), Light Yield with Na-22 source (temperature stabilization better than 1 degree)
- Caltech: Transmittance (L&T, Perkin-Elmer Lambda 950, reproducibility ~0.2%), irradiation with source (Co-60 for 2-30 rad/hr, Cs-137 for ~7000 rad/hr - sources pointlike?), Light Yield with Cs-137 source (systematic uncertainty 1%)
- JLab: Transmittance (L&T, integrating sphere, reproducibility few %), prototype tests (light monitoring and recovery, temperature controlled frame, energy resolution), fADC-based readout and triggering
- Discussion about crystal selection and testing sequence at different institutions
- Select a sample from 10+5 (2014) and from 30 (2015) crystals, then test at one institution, and send sample to the next institution
- Discussion about using PbWO4 crystals at an EIC
- Action item: GEMC of crystal matrix in EIC detector environment
CRYSTALS AT THE DIFFERENT INSTITUTIONS
- IPN-Orsay has BTCP crystals for testing optical and irradiation setup. Ordered 3 CRYTUR crystals and expecting them in January 2016
- CUA has BTCP crystals for testing optical and irradiation setup. Also has one 10-cm long CRYTUR crystal (from Rainer) and one 2x2x2 PbF2 cube from SICCAS (through VSL)
- JLab has 11 SICCAS crystals from 2014 (9 are installed in the prototype, #1 and #4 are available for testing). Also has 30 SICCAS crystals from 2015, which have not yet been tested
- Caltech has 2 crystals from the SICCAS 2014 set (#5 and #11). Plans to do proton irradiation tests at Los Alamos with crystal #11 over next few months
- BNL has 2 crystals from the SICCAS 2014 set (#7 and #15). Plans to have these crystals tested at Caltech before returning
CRYSTAL TEST PLAN
- Select subset of crystals from both 2014 and 2015 by next NPS meeting (December 2015)
- Send crystals to one facility for testing
- Once tests are done send crystals to the next facility. Need to check on logistics for sending crystals to Europe.
CRYSTALS AND EIC
- Discussion about using PbWO4 crystals for the EIC endcap calorimeter and reconfiguring the NPS for that purpose
- Action item: GEMC of crystal matrix (~1000 crystals of dimensions 2x2x20 cm^3) in EIC detector environment
NPS MAGNET
- Discussion about two possible options for NPS magnet steel: parts of existing magnets, e.g., 45D45, or parts from the SBS counterweight
- Additional steel for WACS experiments could be procured through UK funds
- 3D magnet model has been sent to the designer
COLLABORATION MEETING: 21 JANUARY AT JLAB (time: TBD)
- General agenda topics as discussed previously include:
- existing thoughts to make the best optimal photon source needed for the approved polarized WACS experiment, but perhaps also beneficial for other already approved proposals
- updates on the progress with crystal tests/selection procedures
- update on magnet design
- update on PMT HV divider
- possibiliites for Timelike-Compton Scattering measurements with photon beam, NPS and polarized target in Hall C
- ...
ITEMS FOR NEXT MEETING:
- Background simulations
- Plan for crystal testing 2015/16+
- Update on magnet
- Readout
- NPS collaboration meeting planning
- Other...