Line 63: | Line 63: | ||
::: pcal_OutputSampWaveform = 1 | ::: pcal_OutputSampWaveform = 1 | ||
::: pcal_UseSampWaveform = 1 | ::: pcal_UseSampWaveform = 1 | ||
+ | :: and this line to ''DEF-files/PRODUCTION/50k/Full_Replay_50k_SHMS.def'': | ||
+ | ::: block P.cal.* | ||
:: do the replay: | :: do the replay: | ||
:: '' hcana SCRIPTS/SHMS/PRODUCTION/replay_production_shms_coin.C'' | :: '' hcana SCRIPTS/SHMS/PRODUCTION/replay_production_shms_coin.C'' |
Revision as of 05:40, 6 April 2022
Agenda
- DAQ and firmware
- Slow controls
- Decoding software (FADC mode10, VTP data, unblocking)
- Online software (raw displays, gui, interface with ET system)
- Offline reconstruction (clustering algorithm, multi-threading)
- Other business
FADC mode10 decoding update
- Julie, Pramita, Oliver and DJH had a meeting last week to discuss online software development.
- We implemented the changes needed for mode10 decoding to the THcShowerArray and THcShowerPlane classes in hcana (firmware_update branch). This means we can now use the SHMS pre-shower and shower calorimeters as prototypes for histogram / display / gui development.
- In order to do so, we can use data from a series of special mode10 runs taken during the recent PionLT experiment (listed at https://hallcweb.jlab.org/wiki/index.php/PionLT_2021_Physics_Status). The eleven most recent runs (14024 - 14464) have been replayed and root files are available at:
- /work/hallc/nps/dhamilto/mode10
- The files are called:
- shms_coin_replay_production_14XXX_-1.root (run 14557 has the most events, around 130k)
- You can find the corresponding variables in the T tree: eg the waveform branch for the SHMS shower is called P.cal.fly.SampWaveform, while the variables derived from the waveforms are called P.cal.fly.adcSampPulseAmp, adcSampPulseInt, adcSampPulseTime or adcSampPed.
- Very quick and basic example scripts for waveform display:
- SHMS Pre-shower: [1], output Media:SHMS PS Mode10Display.png
- SHMS Shower: [2], output Media:SHMS SH Mode10Display.png
Instructions for replay set up
- If you prefer to set up the full replay chain, brief instructions are given below:
- git clone https://github.com/JeffersonLab/hcana
- cd hcana
- git submodule init
- git submodule update
- git checkout firmware_update
- mkdir build
- cmake -DCMAKE_INSTALL_PREFIX=../ ../ (or cmake3 on some systems)
- git clone https://github.com/JeffersonLab/hcana
- You'll then need to add an $HCANA environment variable and add $HCANA/bin to $PATH and $HCANA/lib64 to $LD_LIBRARY_PATH
- git clone https://github.com/JeffersonLab/hallc_replay_lt
- cd hallc_replay_lt
- git submodule init
- git submodule update
- git clone https://github.com/JeffersonLab/hallc_replay_lt
- Editing and calling SymLinkSetup.sh should help you set up the necessary symbolic links.
- Quite a few of the mode10 runs are already on the cache disks at:
- /cache/mss/hallc/c-pionlt/raw
- Run a replay:
- set the DB_DIR environment variable to ./DBASE (eg source setup.sh)
- add the following lines to PARAM/SHMS/CAL/pcal_cuts.param:
- pcal_arr_OutputSampWaveform = 1
- pcal_arr_UseSampWaveform = 1
- pcal_OutputSampWaveform = 1
- pcal_UseSampWaveform = 1
- and this line to DEF-files/PRODUCTION/50k/Full_Replay_50k_SHMS.def:
- block P.cal.*
- do the replay: