Overview of Configuration after DPAP report (March 2022)
- Location: IP6
- Magnet configuration: 1.5T
- Location of EEEMCAL: inside DIRC
- Position of front face along z = 175cm
- Length along z (including PCB/readout): 60cm
- R_min = 11cm (eta ~3.4)
- R_max = 63 cm (eta ~1.9)
- Modules PWO = 3256 PWO (2.05cm x 2.05cm x 20cm)
- Total weight ~ 3000kg
- Assume: ~500 re-purposed, ~200-250 in-kind
- Readout: assume SiPM 10-15um pixel size (ongoing beam tests on arrays)
Overview of Configurations (June 2021)
- Location: IP6, IP8
- Configuration: 1.5T (ECCE), 2.0T (CORE), 3T (ATHENA)
- Location of EEEMCAL: inside or outside DIRC
Configurations: Location and number of radiator modules
- ATHENA:
- z = 195cm
- R_in = 11 cm (eta ~ -3.5) = R_min_PWO
- R_max_PWO = 53cm (eta ~2) = R_min_Glass
- R_max_total = 100 cm (eta ~ 1.4) = R_max_Glass
- Modules PWO = ~ 2200 (2 x 2 x 20 cm3)
- Modules Glass = ~ 1400 (4 x 4 x 40 cm3)
- Total weight: ~ 2400 kg
- If assume all PWO for this volume: 7600 PWO modules
- Weight ~ 7000 kg
- ECCE:
- z = 190 cm
- R_min = 11cm (eta ~3.5) = R_min_PWO
- R_max_PWO = 49cm (eta ~2) = R_min_Glass
- R_max_total = 57 cm (eta ~1.9) = R_max_Glass
- Modules PWO = 1680 (2 x 2 x 20 cm3)
- Modules Glass = 160 (4 x 4 x 40 cm3)
- Total weight: ~1500 kg
- If assume all PWO for this volume: 2960 PWO modules
- Total weight ~ 2000kg
- CORE
- z = 110cm
- R_min=8.5cm
- R_max=47cm
- Modules PWO = 1412 (2 x 2 x 20 cm3)
- Total weight ~ 1000kg
Mechanical aspects
- Maintenance
- Detector maintenance will be done outside the hall using the mechanism illustrated in these videos:
- How many parts of the detector?
- One part EEEMCal (Athena and ECCE)
- Must we take out the detector?
- All major maintenance will be performed outside the hall
- Where will the detector be mounted?
- On the universal ("DIRC") frame for both Athena and ECCE
- What is keeping the crystals/glass blocks in place?
- Carbon structure between crystals (individual or matrix) - need to know what minimum thickness is required mechanically.
- Where is the detector located?
- Inside DIRC for both Athena and ECCE
- Detector location in z: z=195cm (Athena), z=190cm (ECCE)
- Detector dimensions:
- Athena: Rmin=15cm, Rmax=100cm
- ECCE: Rmin=11cm, Rmax=57cm (support radius=61cm)
- Cooling:
- Need to have as much active area (crystal/glass) as possible to minimize gaps in physics coverage
- Prefer a cooling solution from back and "inside" to minimize any structure outside the crystal/glass block outer radius