General EEEMCal Meeting Summary 7/26/21
Jump to navigation
Jump to search
PARTICIPANTS: Carlos, Cristiano, Crytur, Douglas, Hamlet, Hrachya, Lei, Miroslav, Renee, Richard, Vladimir, Tanja, Rosi,
EEEMCAL IN THE DETECTOR PROPOSALS
ATHENA
- August 1st planned for first simulation campaign
- Opportunity for people to validate calorimeter performance in ATHENA framework
ECCE
- AI supported optimization - in process of getting started
- First simulation campaign included PWO - initial validation completed
SIMULATION UPDATE (Kheagan, Renee)
- Electron ID and Background studies
- e/pi separation
- pair symmetric background
- Started with EEEMCal response in ECCE - next could be ATHENA and CORE
- e/pi very challenging in barrel with current configuration
- Action:
- extract resolution for calorimeter and tracking and compare to Yellow Report to see if fulfill requirements
EEEMCAL DESIGN
- Attachment concept developed - now studying in detail
- Cooling combined: EEEMCal frame and from back
- need also maintain temperature
- Actions:
- check on allowable load
- Crytur prototype: check dissipation of heat from electronics
- INFN prototype: check impact on resolutoin of locating electronics at 15m away
- Impact of aging on heat output - estimation of additional heat output from sphenix?
SIPM+PWO DETECTOR
- Design ongoing
- Aim for including variety of features that will provide information for large detector, e.g., trying to monitor and/or regulate gain/bias and monitor temperature of each channel
BEAM TESTS
- JLAB: prototypes ready, two test beam periods (September ~6-27, November 15-end of run in December)
- DESY: preparations ongoing, prototype expected to be shipped in September
NEXT MEETING: MONDAY 9 AUGUST AT 8:30AM ET