General Meeting Summary 10/31/19

From Cuawiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

MAGNET

  • ODU mapping tests ongoing


HV DIVIDERS

  • All dividers are assembled at Ohio U!
  • 2/3 of the dividers have been tested
  • Discussion about divider non-linearity and impact on physics
  • Level of non-linearity should be less than calorimeter resolution, e.g. if ~<1% non-linearity, then should not affect resolution
  • Based on prototype beam tests, the bypassed version of the amplifier gives the expected resolution
  • design acceptable since resolution ~1%
  • will have effect on positioning, but an be corrected offline - more important is that the PMT survives (anode current ~<100ua)
  • How well can non-linearity be measured? - if known well enough then an always correct
  • Discussion about three new (reduced gain) divider designs recently made by V. Popov
  • Test with LED - find average current of PMT, need to know anode current of PMT
  • Take same PMT and check different types of dividers, e.g. bypassed vs. reduced gain, any improvements?
  • Action Item: Collect information for all existing dividers
  • resolution
  • non-linearity


FRAME - MAGNETIC SHIELDING STUDY

  • Comparing PMT specs and field map suggests that with shielding the field is 50G (transverse) and ~100G (longitudinal), so a significant effect --> must pay attention to shielding
  • current shielding: 1mm mu metal around PMT
  • consider adding soft iron and perhaps additional mu metal around entire box including crystals
  • Discussion of mechanical aspects of adding shielding around the box
  • distance front plate to PMT is 20.3cm - adding shielding should be fine
  • back of box - adding shielding is difficult due to cables, high voltage, etc. Can add an incomplete shielding coverage on the back
  • Discussion of magnetic shielding and predicting the impact on magnetic field where the PMTs are
  • Rough estimate of front magnetic shielding needed:
  • Transverse size of the box is 60cm (30 crystals at 20cm each)
  • Typical PMT shielding expectation is to extend shielding by 1 radius of the photocathode (here use half of the transverse size of the box)
  • Need to extend front shielding by ~30cm
  • Back shielding
  • may not need full 30cm extension since field smaller
  • can leave top/bottom open for ventilation - a hole of 1cm ever two centimeters giving a fractional opening of 50% should be ok for magnetic shielding. Note that could increase the thickness
  • Once decide where all shielding is located (geometry) can do a numerical calculation
  • Based on numerical calculation can also determine if need additional front shielding - may not be needed as long as have extended shielding, impact on resolution small, since have radiation shielding anyway
  • Shielding around magnet to reduce transverse field is difficult - try to avoid
  • Action Items:
  • Finalize shielding dimensions
  • Numerical calculations of magnetic field with additional shielding


FRAME - AIR CIRCULATION

  • Hycal and NPS prototype used nitrogen purge
  • Dry air could work too to remove moisture. Also note that temperature of NPS will be 18 degC compared to 14 degC of HyCal


SIMULATIONS - SOURCE OF RADIATION IN HALL C

  • Geant4 simulation for source tracking developed
  • includes NPS in Hall C geometry
  • includes magnetic field map, but NOT the one that includes a magnetic beam pipe for shielding and proper propagation to the beam dump
  • Validation: Results show that the major sources of radiation are the target and the next critical radius (here, beam pipe 2)
  • consistent with expectation for any beam calculation - expect ~1/3 of radiation from these sources
  • observation that have a source from top/bottom of pipe consistent with vertical bend magnet
  • What fraction of background radiation is produced in a specific area?
  • Simulate the shielding in front of the calorimeter with a cut of 10 MeV on the calorimeter distribution
  • Should check the Geant4 default cut - likely is ~100keV
  • Analyze the fraction of particles with <10 MeV and >10 MeV
  • if only have 10 MeV particles can shield
  • Results indicate not much reduction in background radiation even with shielding
  • seems counter-intuitive
  • what magnetic field was used? - need to use the one where have shielding around beam pipe 2
  • discussion about Opera plots of magnetic field - even after magnet there is a big spike (large fields), so need additional shielding
  • additional shielding was implemented in form of a magnetic beam pipe
  • Action Items:
  • Include corrected field map
  • Page 4: make 1D histogram to determine where one has to pay attention


CRYSTALS

  • 64 additional Crytur crystals arrived and have been tested - total number: 414
  • Additional 40 crystals from Crytur are on the way


CRYSTAL PUBLICATION

  • Draft will be circulated in week 11/4 for comments


COLLABORATION MEETING: 3 FEBRUARY 2020 AT JLAB

  • Draft agenda will be subject of discussion for next NPS phone meeting
  • So far suggested agenda items - please send additional suggestions for agenda items to hornt@cua.edu
  • Magnet mapping results
  • HV dividers


NEXT MEETING: THURSDAY 21 NOVEMBER AT 9:00AM (ET)