General Meeting Summary 10/5/17

From Cuawiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

NPS COLLABORATION MEETING - JANUARY 2017

  • Date will be in the week of the Hall A/C meeting - exact choice will depend on NPS meeting agenda
  • Please send suggestions for talks by 19 October to hornt@cua.edu
  • Note: Compact Photon Source Meeting will be together with NPS meeting


NPS SUBSYSTEM UPDATES

  • PMTs and HV Dividers
  • New PMTs were delivered with slightly different sockets - requires machining (or, if doesn't work get back to Hamamatsu)
  • 100 of the new PMTs were given to Hall D for assembly and tests
  • 1-2 new PMTs ready to be shipped to IPN-Orsay for assembly and tests
  • Assembly drawings of PMT+crystal module from HyCal are being collected - action item: get the original drawings from designers
  • similar to HMS calorimeter, but dimensions different and PbWO4 more fragile
  • found that in actual HyCal PMTs were NOT glued to crystal (that was only done for prototype modules)
  • OU got a quote for HV divider components (Advance Assembly) - checking the details, if all looks ok, will go ahead with the full procurement
  • PbWO4 Crystals
  • Discussion of visual inspection and dimension measurements with caliper of box#3 (10 crystals) of the first set of 160 SICCAS crystals
  • Visual inspection shows that about half of these crystals have bubbles and/or chipped edges - according to data the company sent, this does not affect optical properties
  • Action item: post the data the company sent
  • Discussion about alternative measurement methods to make nondestructive measurement of crystal dimensions that is safer (and potentially faster) than measuring with caliper
  • Note: current labor for measuring dimensions with calipers for 10 crystals (1 box) is 1 week
  • Best choice for purchasing a measurement system seems a dimension gage with tough probe
  • Probe has a sphere/ball tip at end, so can slide along crystal without visible scratching
  • Current plan is to measure transverse dimensions at three points along the crystal moving the probe
  • There is also an existing automated dimension measurement instrument in the machine shop owned by accelerator. For Hall A DVCS, this facility was available to the collaboration. This seems to have changed and now one cannot perform measurements oneself any longer.
  • What is the cost for using machine shop or a local company to make dimension measurement of 100s of crystals?
  • Initial crystal optical measurements performed at CUA for SICCAS 5031-5040 (box #3, first set of 160 pieces delivered in Sept 2017)
  • Initial results of subset of two suggest low light yield compared to requirement
  • Reference crystal results have been stable to 0.5 pe/MeV for more than a year
  • NPS magnet
  • All still seems on schedule for yoke and main coil delivery later this year
  • Frame
  • Design work ongoing including prototype module design (PMTs will not be glued to crystal)
  • Evaluation of specs for LED curing system
  • New graduate student implementing geometry in simulation to study effect of material


NEXT MEETING: THUR 2 NOVEMBER at 9:00 AM (EST)