General Meeting Summary 11/16/17

From Cuawiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

NPS Collaboration Meeting set for Tuesday, 23 January 2018, following the Hall C meeting

FRAME DESIGN AND CONSTRUCTION

  • Discussion about an update from Mike Fowler on design status and plans
  • idea is to complete the general design drawings based on HyCal with all pieces fitted together and then send them to IPNO for fabrication design drawing
  • crystal length is 20cm, the detector box on order 1m to provide enough space to work
  • connectors will be on top
  • box includes Cu plates (shown in orange) from sides only - this will give a temperature gradient
  • hinged doors for access from all sides during installation
  • option for ventilation in box would be good
  • largest tolerable vertical offset expected on order 1cm
  • rail design similar to DVCS
  • Discussion about prototype design and what parts might be adaptable for full frame design
    • prototype consists of a copper box, a "Front Plate" and a "Back Plate" made by 3D printing technology from some plastic (could also be a mesh box such as using for bottles transportation from carbon-fiber),
  • Tests show that such a design for a 9x9 crystal matrix can hold 10 kg vertical pressure with 50 mkm deformation
  • prototype assembling procedure:
  • clean PbWO crystals after testing and selection, wrap with Teflon and Tedlar paper and keep in clean room (ready for stacking)
  • Mount "Front Plate" (see picture links in Agenda) inside of Cu Box
  • Stack all Crystals; fix their positions relative the side walls.
  • Mount "Backplate" and will check that positions of crystals-and holes for PMTs are OK.
  • Mount PMTs with tensioning rod and pushed towards crystal. For crystal-PMT optical contact use optical grease (Saint Gobain, organic scintillator, Bicron630).
  • Monitoring can be done from the front side using ~100 mkm diameter quartz fibers. For the full detector, a set of LED could be located on the back of the calorimeter and below beam level (to minimize radiation damage). For the prototype, this procedure was tested in Hall A.
  • For curing system, prototype uses "UV curing", a separate frame holds high intensity Lamps (as for BigCal) and

curing would be done in a beam off period

  • Discussion about full detector frame design
  • Design geometry optimization ongoing at IPNO - finalization anticipated beginning of 2018
  • Current design has two sets of LEDs from back for curing and monitoring - tests of curing efficiency, also including fibers to deliver light to specific locations, ongoing


MAGNET

  • Main coil construction is on schedule, pictures of preliminary assembly shown, company still needs to perform final checks
  • Iron cut pictures for the yoke are shown - looks like ready to ship
  • First task when pieces arrive is to test iron - this can be done before the main coil arrives


CRYSTAL/PMT UPDATE

  • Visual inspection identified two boxes of crystals (20/100) that seem not new (traces of old labels, chemical film)
  • After consulting with material science, best course of action for these would be to send back to company
  • Optical measurements and microscopy of identify individual crystals out of a set of 100 with major flaws like bubbles and deep pits in the bulk
  • Mechanical measurement tool has arrived, accuracy is 1um.
  • still need a granite table to optimize the setup
  • Measurement of PMT mechanical properties shows that:
  • diameters are consistent with specifications
  • diameters are consistent from PMT-to-PMT
  • DAQ system in clean room needs to be setup for PMT (relative quantum efficiency) and prototype tests
  • These tests could be and some are already done in collaboration with Hall D
  • A. Somov mentions that he has many components for setting up a DAQ


NEXT MEETING: THUR 7 DECEMBER 2017 at 9:00 AM (EST)