Difference between revisions of "General Meeting Summary 3/21/13"

From Cuawiki
Jump to navigation Jump to search
(Created page with "BACKGROUND STUDIES/DETECTOR * Three possible options for the beam pipe assembly are presented. For the Neutral Particle Spectrometer (NPS) at 8 degrees with: ::* the existing l...")
 
 
Line 9: Line 9:
 
::* the small angle beam piple assembly HMS angles are limited to >=10.5 degrees (8.6 mr critical angle)
 
::* the small angle beam piple assembly HMS angles are limited to >=10.5 degrees (8.6 mr critical angle)
  
* Format of energy spectra and energy distributions for different particles presented seem suitable for simulations. Note that spectra are presented without sweeping magnet. To include sweeping magnet add a cutoff at 300 MeV (see p. 38/39 in PAC39 proposal).
+
* Format of energy spectra and energy distributions for different particles presented seem suitable for simulations. Note that spectra are presented without sweeping magnet. To include sweeping magnet add a cutoff at 300 MeV (see [http://www.jlab.org/exp_prog/proposals/12/C12-11-102.pdf p. 38/39 in PAC39 proposal]).
  
 
* Some discussions on choice of crystal dimensions. Smaller dimensions are favorable for background rate per block
 
* Some discussions on choice of crystal dimensions. Smaller dimensions are favorable for background rate per block

Latest revision as of 13:46, 29 March 2013

BACKGROUND STUDIES/DETECTOR

  • Three possible options for the beam pipe assembly are presented. For the Neutral Particle Spectrometer (NPS) at 8 degrees with:
  • the existing large angle beam pipe assembly, HMS angles are limited to >= 15 degrees (17.5 mr critical angle)
  • a modified, "three-section" large angle beam pipe assembly HMS angles are limited to >=13 degrees
  • the small angle beam piple assembly HMS angles are limited to >=10.5 degrees (8.6 mr critical angle)
  • Format of energy spectra and energy distributions for different particles presented seem suitable for simulations. Note that spectra are presented without sweeping magnet. To include sweeping magnet add a cutoff at 300 MeV (see p. 38/39 in PAC39 proposal).
  • Some discussions on choice of crystal dimensions. Smaller dimensions are favorable for background rate per block


ITEMS FOR NEXT MEETING:

  • Need to check how critical smallest HMS angles below 13 degrees are for the experiment kinematics
  • Once decison on beam pipe is made, evaluate the fraction of background from target vs. beam line components.


NEXT MEETING: THUR, 28 MARCH at 9AM (EST)