General Meeting Summary 9/14/17

From Cuawiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

CRYSTALS

  • 160 SICCAS crystals arrived - 16 boxes with 10 crystals/box
  • All crystals are labeled
  • Visual inspection shows small scratches (< 1 mm) on surfaces, some crystals have features inside
  • discussion how to quantify effect of surface effects on crystal response
  • Started mechanical measurements, e.g. dimensions
  • Required dimensions are 2.05cm x 2.05 cm x 20.0 cm (+-50um tolerance on sides, +- 150 um for length)
  • Measured dimensions are 2.10cm x 2.10 cm wity 0.09 mm uncertainty using caliper - looking for better measurement instrumentation
  • Status of Crytur crystal production
  • Still working on meeting radiation resistance variation requirements
  • Most measurements performed at Giessen though for different geometry crystals
  • Some open questions on rectangular crystal quality - being investigated at CUA


MAGNET

  • Anticipated delivery dates for yoke is end of month (main coil is delayed until end of year)
  • Test plan discussion
  • Hall probe for tests identified and available
  • Information needed for initial test plan: space requirements and what measurements will be performed
  • need details of power needed and for what - initial discussions with Hall have started (Bogdan)


FRAME - DISCUSSION OF INITIAL FRAME DESIGN ASSEMBLY

  • Need correct values for: crystals and dimensions, PMT dimensions, HV divider dimensions
  • Curing system
  • plan is to use 2 blue and 2 red LEDs at the four corners of the crystal
  • assume LED diameter 2mm, which is smaller by about a factor of two than what was previously used for NPS 3x3 prototype
  • assume LEDs will be placed at the back to avoid radiation damage even though placement may be less efficient for curing
  • Mechanical connection PMT to crystal
  • currently assume spring-based system similar to 3x3 NPS prototype, alternatively could try some structure from front
  • Note: Hycal design glued PMT to crystal, not very flexible
  • Nominal NPS design assumes optical connection PMT to crystal is with an organic scintillator (optical grease like Bicron 630)
  • Crystal dimensions and reflector
  • Nominal NPS design reflector is teflon, expected crystal-to-crystal variation in thickness is expected to be on order 20-50um, similar to the uncertainty in crystal dimensions
  • for frame, standard principle would be to compress entire crystal stack and temperature regulation, so thickness variation on that level may not be an issue
  • Electronic ports at back of PMT
  • Design assumes that all cables come outside the box on the top towards the back using rotatable channels - designer is working on the details and also eliminating remaining mechanical interference


ACTION ITEMS

  • Crystals - start characterization of 160 SICCAS crystals and record results,
  • Magnet - write test plan including space requirements and what measurements will be performed
  • Frame - continue design work and curing system studies, check dimensions of HV divider with OU, need input on mechanical interference and electronics connection at back from JLab designer, need a few R4125 PMTs with bases for testing
  • HV dividers - continue procurement of PMTs and divider components
  • NPS collaboration meeting - start thinking about dates and coordination with JLab meetings in 2018


NEXT MEETING: THURSDAY 5 OCTOBER at 9:00 AM (EDT)