Special Meeting Grounding Scheme Summary 9/22/21

From Cuawiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

PARTICIPANTS: Carlos, Fernando, Thi, Emmanuel, Vladimir, Tanja, Brad

DISCUSSION GROUND BETWEEN PCB AND ALUMINUM PART

  • Option to connect PCB+aluminum part
  • Enclosure already grounded through mechanical attachment to structure - cannot isolate detector from support structure
  • mu metal shield already connected to mechanical structure
  • make sure that shielding ground (through mechanical structure) is separate from electronics ground
  • Can put provision on PCB board for additional grounding - activating this feature would take some labor though (unplug, activate, reinstall, etc.)
  • general agreement that it captures all features of NPS grounding
  • next: put sketch into CAD for more detailed discussion
  • Main NPS box isolated from carriage
  • How to test grounding scheme
  • can do some tests in the lab - some simulations possible
  • ultimately will have to test when all is assembled
  • Need information on position of connector on PCB
  • Action items:
  • generate CAD for NPS grounding
  • finalize design of PCB - need position of connector
  • test optimized divider (Vladimir)
  • Estimated timeline:
  • finalize PCB design
  • prototype new PCB and testing
  • production - should be in place by end of the year