Special Meeting LV Cable Strategy Summary 9/15/21

From Cuawiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

PARTICIPANTS: Fernando, Bogdan, Carlos, Emmanuel, Vladimir, Tanja


DISCUSSION LOW VOLTAGE STRATEGY

  • Choice of cables
  • Size of cables: 22 AWG (thicker cable) instead of 24 AWG?
  • worth looking into if there is a solution that offers lower resistivity
  • however, need to pay attention to size of connectors that fit on board, etc.
  • Is there a AWG available to handle one column?
  • Action Items:
  • Review calculation and see what cable + connector combination would be possible
  • Fernando provide an example of a cable that would work - Orsay team can then optimize
  • Option of Voltage stabilizer/regulator
  • would have additional power dissipation but provides stabilization
  • obtaining negative regulators may be challenging
  • if components available then good thing to so (as long as power dissipation not an issue)
  • Review of power consumption:
  • (optional) stabilizer power consumption ~<20mW (for +- means ~40mW)
  • (need) one amplifier dissipates ~120mW
  • (need) one divider disspates ~500mW - defines cooling capacity
  • total power dissipation increases to ~660mW (originally assumed ~500mW cooling capacity)
  • Action item:
  • Is cooling capacity sufficient to handle LV? - 660mV instead of 500mW --> need to test

HV DIVIDERS

  • Plan final tests next week
  • Action Item: Vladimir check setup on Monday
  • Final Layout
  • Production