Difference between revisions of "February 7th, 2018"

From kl project
Jump to navigation Jump to search
Line 4: Line 4:
 
* ''Just a reminder'': We will have PKI2018 Workshop, Feb 14-15 [https://www.jlab.org/conferences/pki2018/]
 
* ''Just a reminder'': We will have PKI2018 Workshop, Feb 14-15 [https://www.jlab.org/conferences/pki2018/]
  
* KL Flux Monitor: Mikhail sent KL Flux Memo to Eugene [https://wiki.jlab.org/klproject/images/e/ec/FluxMonitor_Memo_v2.pdf]
+
* KL Flux Monitor: Mikhail sent KL Flux Memo to Eugene. The weight of the device is 1.1 ton.
 +
[https://wiki.jlab.org/klproject/images/e/ec/FluxMonitor_Memo_v2.pdf].
  
 
* CFS: Tanja posted a draft of the NPS/CPS 2018 Action Items: [https://wiki.jlab.org/cuawiki/images/6/64/NPS_2018_Action_Items.pdf].
 
* CFS: Tanja posted a draft of the NPS/CPS 2018 Action Items: [https://wiki.jlab.org/cuawiki/images/6/64/NPS_2018_Action_Items.pdf].
  
* Sc & cryotarget: A week ago, Justin, Eric, Chris, and Igor met and discuss a SC and LH2/LD2 cryotarget configuration.  The bottom line is that the cryotarget will have 6 cm in diameter and 40 cm length and it will fit a SC scattering chamber. The cryotarget location is in the center of the GlueX detector.There is a minor question regarding a production angle for different particles for different reactions which somehow depends on the cryotarget location.
+
* SC & cryotarget: A week ago, Justin, Eric, Chris, and Igor met and discuss a SC and LH2/LD2 cryotarget configuration.  The bottom line is that the cryotarget will have 6 cm in diameter and 40 cm length and it will fit a SC scattering chamber. The cryotarget location is in the center of the GlueX detector.There is a minor question regarding a production angle for different particles for different reactions which somehow depends on the cryotarget location.
  
 
* Mikhail's calculations for KLp-->K+n (K+ production angle in CM vs energy) [https://wiki.jlab.org/klproject/images/5/5d/KPlus_N_acceptance.gif] (left: all, right cos(Theta)> -0.95). Kaons from the center of the cryotarget will be detected up to 126 deg in CM.
 
* Mikhail's calculations for KLp-->K+n (K+ production angle in CM vs energy) [https://wiki.jlab.org/klproject/images/5/5d/KPlus_N_acceptance.gif] (left: all, right cos(Theta)> -0.95). Kaons from the center of the cryotarget will be detected up to 126 deg in CM.

Revision as of 20:23, 6 February 2018

  • Attended:


  • Just a reminder: We will have PKI2018 Workshop, Feb 14-15 [1]
  • KL Flux Monitor: Mikhail sent KL Flux Memo to Eugene. The weight of the device is 1.1 ton.
[2]. 
  • CFS: Tanja posted a draft of the NPS/CPS 2018 Action Items: [3].
  • SC & cryotarget: A week ago, Justin, Eric, Chris, and Igor met and discuss a SC and LH2/LD2 cryotarget configuration. The bottom line is that the cryotarget will have 6 cm in diameter and 40 cm length and it will fit a SC scattering chamber. The cryotarget location is in the center of the GlueX detector.There is a minor question regarding a production angle for different particles for different reactions which somehow depends on the cryotarget location.
  • Mikhail's calculations for KLp-->K+n (K+ production angle in CM vs energy) [4] (left: all, right cos(Theta)> -0.95). Kaons from the center of the cryotarget will be detected up to 126 deg in CM.
  • KL beam: Ilja made MC for KL beam and he promised to provide a geometrical profile (size and angle) of KL beam on the cryotarget. The size of the KL beam is much broader than the size of the diameter of the cryotarget.
  • Final design of Be-target assembly [5].The weight of the Be-target assembly is 14.5 ton. Preliminary results show that we are under RadCon control [6]. We are waiting for Tim and his thoughts for a cooling system.