KLF beamline meeting - December 12, 2024
Jump to navigation
Jump to search
Agenda
- Announcements
- Beamline studies with GEANT4 (Richard)
- Updates on KFM (Mikhail)
- Any other business
Minutes
Present: Igor, Tim, Moskov, Beni, Sashi, Marshall, Eugene, Richard
- Eugene announced that the capital budget funding is frozen until March until the source of SOLID funds is understood. If capital construction budget is used for SOLID, that would mean about factor of two reduction of capital funding rate for other projects.
- The next run (after the spring run) will be in the fall of 2025, not in winter of 2026. It will end sooner.
Richard was busy with exam work. Meanwhile, the university IT division delete his file by formatting the disks. Richard has backups of his data from GEANT4 simulations, and he is recovering it. Richard may have plots next week.
- Hovanes performed thermal analysis for the AC with 20% radiator. He did it assuming both water cooling and air cooling. For water cooling scenario, Hovanes considered both isotropic and anisotropic material for Boron Nitride cup of AC. Richard thinks that the cup is isotropic since it does not feel like a crystal but feels like ceramic.
- Water cooling analysis showed that the tungsten temperature will be fine, below 100 degrees Celsius if cooled through the edges of the BN cup.
- Air-cooled analysis shows that the temperature of the tungsten may reach 450 degrees Celsius, and aluminum plate may reach 400 degrees.
- Richard pointed out that having solid tungsten blocks instead of pins with a base may overestimate the power deposition in the pin are by about a facto of 4. So, the temperatures might be overestimated. Hovanes mentioned that because of the coarse binning of the power deposition, some of the power was not included in the volume of AC in the termal analysis, thus slightly reducing the temperature.
We may have a meeting on December 19th, if there is material to discuss.