List of systematics:
+
List of systematic uncertainties:
  
 
== Setup ==
 
== Setup ==
 
=== Misalignment in position reconstruction ===
 
=== Misalignment in position reconstruction ===
 +
* expected: ~ 0.7 mm
 +
* measured:
 
=== Longitudinal position uncertainty ===
 
=== Longitudinal position uncertainty ===
 +
* measured:
 
=== Calorimeter energy miscalibration ===
 
=== Calorimeter energy miscalibration ===
 +
* measured: < 0.2% of E (Maxime)
  
 
== Normalization ==
 
== Normalization ==
 
=== Ratio in geometrical acceptance (method dependent) ===
 
=== Ratio in geometrical acceptance (method dependent) ===
 +
* expected: 0.4% (including Q<sup>2</sup> determination)
 +
* measured:
 
=== Ratio in detection efficiency (method dependent) ===
 
=== Ratio in detection efficiency (method dependent) ===
 +
* expected: <0.1%
 +
* measured:
 +
=== Q<sup>2</sup> smearing ===
 +
* measured:
  
 
== Radiative correction (event selection) ==
 
== Radiative correction (event selection) ==
 +
* expected: 0.3%
 +
* measured:
  
 
== Fitting procedure ==
 
== Fitting procedure ==
 +
* expected: 0.2%
 +
* measured:

Latest revision as of 11:27, 22 May 2017

List of systematic uncertainties:

Setup

Misalignment in position reconstruction

  • expected: ~ 0.7 mm
  • measured:

Longitudinal position uncertainty

  • measured:

Calorimeter energy miscalibration

  • measured: < 0.2% of E (Maxime)

Normalization

Ratio in geometrical acceptance (method dependent)

  • expected: 0.4% (including Q2 determination)
  • measured:

Ratio in detection efficiency (method dependent)

  • expected: <0.1%
  • measured:

Q2 smearing

  • measured:

Radiative correction (event selection)

  • expected: 0.3%
  • measured:

Fitting procedure

  • expected: 0.2%
  • measured: