Difference between revisions of "Systematics"
From Pcrewiki
Jump to navigationJump to search(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | List of | + | List of systematic uncertainties: |
== Setup == | == Setup == | ||
=== Misalignment in position reconstruction === | === Misalignment in position reconstruction === | ||
− | * expected: | + | * expected: ~ 0.7 mm |
* measured: | * measured: | ||
=== Longitudinal position uncertainty === | === Longitudinal position uncertainty === | ||
− | |||
* measured: | * measured: | ||
=== Calorimeter energy miscalibration === | === Calorimeter energy miscalibration === | ||
− | + | * measured: < 0.2% of E (Maxime) | |
− | * measured: | ||
== Normalization == | == Normalization == | ||
=== Ratio in geometrical acceptance (method dependent) === | === Ratio in geometrical acceptance (method dependent) === | ||
− | * expected: | + | * expected: 0.4% (including Q<sup>2</sup> determination) |
* measured: | * measured: | ||
=== Ratio in detection efficiency (method dependent) === | === Ratio in detection efficiency (method dependent) === | ||
− | * expected: | + | * expected: <0.1% |
* measured: | * measured: | ||
+ | === Q<sup>2</sup> smearing === | ||
+ | * measured: | ||
== Radiative correction (event selection) == | == Radiative correction (event selection) == | ||
+ | * expected: 0.3% | ||
+ | * measured: | ||
== Fitting procedure == | == Fitting procedure == | ||
+ | * expected: 0.2% | ||
+ | * measured: |
Latest revision as of 12:27, 22 May 2017
List of systematic uncertainties:
Setup
Misalignment in position reconstruction
- expected: ~ 0.7 mm
- measured:
Longitudinal position uncertainty
- measured:
Calorimeter energy miscalibration
- measured: < 0.2% of E (Maxime)
Normalization
Ratio in geometrical acceptance (method dependent)
- expected: 0.4% (including Q2 determination)
- measured:
Ratio in detection efficiency (method dependent)
- expected: <0.1%
- measured:
Q2 smearing
- measured:
Radiative correction (event selection)
- expected: 0.3%
- measured:
Fitting procedure
- expected: 0.2%
- measured: