Difference between revisions of "HyCal PMT Electrical Testing Pictures"
From Pcrewiki
Jump to navigationJump to searchLine 9: | Line 9: | ||
[[File:C05-027_Good.PNG|500px|C05#027_Good]] [[File:C05-028_GoodBig.PNG|500px|C05#028_GoodBig]] | [[File:C05-027_Good.PNG|500px|C05#027_Good]] [[File:C05-028_GoodBig.PNG|500px|C05#028_GoodBig]] | ||
− | After testing all PbWO<sub>4</sub> there remained 2 bad modules. These modules were | + | After testing all PbWO<sub>4</sub> there remained 2 bad modules. These modules were C06#022 (W15 [1015]) and C09#134 (W889 [1889]) with the former giving poor wide signals (seen below) and the other not responding at all. |
+ | |||
+ | [[File:C06-22_Bad.PNG|500px|C06#022_Bad]] |
Latest revision as of 15:44, 6 November 2024
Below are photos of the work and work setup of the PMT Electrical Tests:
Below are images of the PMT for some notable PMTs and some good ones to keep track of any issue modules with convention "C[Column #]#[Connector #]". These are from October 22, 2024 with other PMT responses that have been captured available in their corresponding Log Post on the PRad Logbook:
After testing all PbWO4 there remained 2 bad modules. These modules were C06#022 (W15 [1015]) and C09#134 (W889 [1889]) with the former giving poor wide signals (seen below) and the other not responding at all.