Difference between revisions of "Systematics"
From Pcrewiki
Jump to navigationJump to searchLine 1: | Line 1: | ||
− | List of | + | List of systematic uncertainties: |
== Setup == | == Setup == |
Latest revision as of 11:27, 22 May 2017
List of systematic uncertainties:
Setup
Misalignment in position reconstruction
- expected: ~ 0.7 mm
- measured:
Longitudinal position uncertainty
- measured:
Calorimeter energy miscalibration
- measured: < 0.2% of E (Maxime)
Normalization
Ratio in geometrical acceptance (method dependent)
- expected: 0.4% (including Q2 determination)
- measured:
Ratio in detection efficiency (method dependent)
- expected: <0.1%
- measured:
Q2 smearing
- measured:
Radiative correction (event selection)
- expected: 0.3%
- measured:
Fitting procedure
- expected: 0.2%
- measured: