Search results

Jump to navigation Jump to search
  • ** Carlos - [[Media:High current polarized gun for positrons - slides for April 6 2022 meeting.pptx]] == Upcoming events... ==
    842 bytes (118 words) - 10:51, 6 April 2022
  • ...this outline for a new scheme to readout the delayed helicity for Physics Events Trigger (instead of using Scalers RingBuffer): # Report current seed value
    580 bytes (84 words) - 12:53, 20 May 2015
  • ** Carlos' e-gun proposal slides [[media:DRAFT 2 Slides for Joe on the high current polarized HV gun plans.pptx]] == Upcoming events... ==
    2 KB (240 words) - 07:09, 23 March 2022
  • # Measure neutron events in chamber. Neutron radiation detectors in injector region will indicate if # Measure rate vs beam current (0.01, 0.1 and 1.0 µA)
    7 KB (1,106 words) - 11:54, 4 May 2018
  • ...s Carlos' ERL09 presentation about similar observations while running high current in the FEL gun: [[Media:FEL-Photocathode-'arcing'-ERL09.pdf]] ...cern.ch/accelconf/ERL2013/talks/wg103_talk.pdf Bruce Dunham's talk on high current cathode damage]
    2 KB (403 words) - 07:00, 26 September 2016
  • ...tried to reach 1 mA (300kV) stable running, but the gun HVPS trips off on current a few minutes later, max time is about 30 minutes, see link here: [https:// ...did not seem to help much. What it seemed to help is to increase the beam current SLOWLY.
    5 KB (919 words) - 11:04, 5 July 2016
  • ...edia:Hel_8218_0.txt]] shows that S1 helicity is lacking FADC by 0 to a few events. FADC helicity is correct because it is read event by event in the same mod :* Mott Mott_Sample 8314, (FADC+TDC+Scalers), beam current = 0.9 uA.
    4 KB (608 words) - 18:07, 2 April 2015
  • # Measure neutron events in chamber. Neutron radiation detectors in injector region will indicate if # Current scan: 0.5 uA for 1 hour, 0.25 uA for 2 hours
    7 KB (955 words) - 16:24, 20 July 2018
  • In the meantime, the Run 1 wiki has been updated run a chronology of events/logbook entries and the final on-line spreadsheet of runs and on-line resul : Beam current
    3 KB (403 words) - 19:19, 5 February 2015
  • * To run large statistics run (using LUMI events): * The current geometry for the Bubble Chamber is in gemc and is shown below:
    12 KB (1,732 words) - 10:23, 27 February 2017
  • - Electron Dump: isolated to measure beam current, 2 kW dump. Make sure no neutrons are produced in the ceramic insulator - Discriminate between (γ,α) and (γ,n) events using the acoustic signal. The acoustic signal may help to
    4 KB (618 words) - 14:17, 27 February 2014
  • #'''Measure asymmetry vs. dead-time and beam current [[Media:Deadtime_spreadsheet.ods]]''' #Determine number of events needed for IHWP=IN and OUT
    8 KB (1,322 words) - 10:35, 17 March 2015