Difference between revisions of "Kerr - August 5, 2016"

From Ciswikidb
Jump to navigation Jump to search
Line 1: Line 1:
 
[[file:Puckgeometry.jpeg|thumb|upright=2.5|Use this to interpret Excel descriptions.]]
 
[[file:Puckgeometry.jpeg|thumb|upright=2.5|Use this to interpret Excel descriptions.]]
  
'''Initital NEAR Trials with Steel only'''
+
'''1.'''
 +
'''NEAR Trials with Steel only'''
  
The following excel file describes measurements done with;
+
The following 'a.' and 'b.' describes measurements done with;
* STEEL puck only
+
* STEEL puck only, {with the exception of a mirror null}
 
* Angle between laser and photodiode 38.6 -+2.4 degrees
 
* Angle between laser and photodiode 38.6 -+2.4 degrees
 
* The Setup was "NEAR" The solenoid
 
* The Setup was "NEAR" The solenoid
* Center of Optics Stage 58 -+ 1 cm from puck
+
* Center of Optics Stage {between Laser and Photodiode} 58 -+ 1 cm from puck
  
-->->->[[media:NearSetup.xlsx]]
+
a. -->->->[[media:NearSetup.xlsx]]
 +
 
 +
Then Puck stability was investigated
 +
 
 +
b. -->->-> [[media:Puckchanges.xlsx]]
 +
 
 +
 
 +
'''2.'''
 +
'''FAR trials with STEEL and Moly'''
 +
 
 +
The following file describes measurements done with;
 +
* STEEL and MOLY and a Mirro
 +
* Angle between laser and photodiode 5.31 -+0.45 degrees
 +
* The Setup was "FAR" from The solenoid
 +
* Photodiode 140 cm -+ 2 cm from puck

Revision as of 17:12, 5 August 2016

Use this to interpret Excel descriptions.

1. NEAR Trials with Steel only

The following 'a.' and 'b.' describes measurements done with;

  • STEEL puck only, {with the exception of a mirror null}
  • Angle between laser and photodiode 38.6 -+2.4 degrees
  • The Setup was "NEAR" The solenoid
  • Center of Optics Stage {between Laser and Photodiode} 58 -+ 1 cm from puck

a. -->->->media:NearSetup.xlsx

Then Puck stability was investigated

b. -->->-> media:Puckchanges.xlsx


2. FAR trials with STEEL and Moly

The following file describes measurements done with;

  • STEEL and MOLY and a Mirro
  • Angle between laser and photodiode 5.31 -+0.45 degrees
  • The Setup was "FAR" from The solenoid
  • Photodiode 140 cm -+ 2 cm from puck