OPS Network
Mott DAQ Host:
name => opsmdaq0 ip => 129.57.236.240
Mott DAQ IOC:
name => iocmdaq1 ip => 129.57.236.241
Other network information:
name => opsnet number => 129.57.236.0 mask => 255.255.252.0 cidr => 22 hexmask => 0Xfffffc00 broadcast => 129.57.239.255 gateway => 129.57.236.1 domain => acc.jlab.org vlan => 5 comment => OPS
Mott DAQ iocmdaq1
There are two ways to access the Mott DAQ ioc:
- From an accelerator machine: telnet iocmdaq1
- From an accelerator machine: ioc_concole iocmdaq1. Here you need to enter a password to this cannot be done with the idaq account.
The startup file: idaq@opsmdaq0:/cs/op/iocs/iocmdaq1/startup
The CODA boot file: idaq@opsmdaq0:/opt/coda/boot/mott_roc1.boot
CODA Files
CODA crl files are in: idaq@opsmdaq0: /opt/idaq/crl Scalers.crl Mott_Sample.crl Mott_SemiInt.crl PEPPo_Int.crl To compile: makelist Mott_Sample.crl ppc
CODA scripts files are in: idaq@opsmdaq0: /opt/idaq/scripts
Summary of CODA Configurations
Name | Readout | Output | Trigger |
Scalers | Scaler S1 (helicity gated), S2 (un-gated) | Scalers_%d.dat | Delayed nT_Settle |
Mott_Sample | Mott FADC, S1, S2, TDC | Mott_Sample_%d.dat | Mott Detector |
Mott_SemiInt | Mott FADC, S1, S2, TDC | Mott_SemiInt_%d.dat | Mott Detector |
PEPPo_Int | INT FADC, S1, S2 | PEPPo_Int_%d.dat | nT_Settle |
Backup Data Files to SILO
Cron scripts are installed on the idaq account on opsmdaq0 to back up data and delete it from /data and /data1:
/opt/idaq/cron/cron_opsmdaq0
Do not attempted to copy, delete, move, or rename files. Never !
The scripts assume that data appears in /data*/DIR where DIR = "annihilation" or "compton" or "mott" Files must have the keywords "PEPPo" or "Scalers" or at least "dat". This avoids writing scratch files like root output. Do not start putting data in some new place or with new names. It won't be backed up to MSS if you do that.
The data are deleted from local disks if they have been written in duplicate with correct byte count to the MSS tape silo. The data stay on disk for an amount of time that is related to the amount of disk space is available. If lots of disk available, the data stay forever. If not much disk, the data are deleted aggressively.
The data is copied to: /mss/accel/peppo/raw
The copying of data was disabled on January 3rd, 2014.
Mott FADC
const FADC_ADDR = 0x680000 # 12 bit fADC MOTT - Slot 7 const FADCMODE = 1 (Mott_Sample) const FADCMODE = 3 (Mott_SemiInt) const FADCSLOT_Mott = 7 const TRSPLIT = 0xeb13 # Address of fADC Signal Distribution Module
CH1 - E LEFT Range - 0.5 V DAC_offset = 3300 CH2 - E RIGHT - 0.5 V DAC_offset = 3300 CH3 - E UP - 0.5 V DAC_offset = 3300 CH4 - E DOWN - 0.5 V DAC_offset = 3300 CH5 - dE LEFT - 0.5 V DAC_offset = 3300 CH6 - dE RIGHT - 0.5 V DAC_offset = 3300 CH7 - dE UP - 0.5 V DAC_offset = 3300 CH8 - dE DOWN - 0.5 V DAC_offset = 3300 CH9 - BFM - 1.0 V DAC_offset = 3300 CH10 - Empty - 1.0 V DAC_offset = 3300 CH11 - Mott Trigger - 1.0 V DAC_offset = 3300 CH12 - Empty - 1.0 V DAC_offset = 3300 CH13 - Delayed Hel - 1.0 V DAC_offset = 3300 CH14 - T_Settle - 1.0 V DAC_offset = 3300 CH15 - Pat Sync - 1.0 V DAC_offset = 3300 CH16 - Pair Sync - 1.0 V DAC_offset = 3300
Reference: JLab Module Manuals [1]
Reference: Media:FADC250_V2_ADC_FPGA_V5.pdf
INT FADC
const FADC_ADDR = 0xed0000 # 12 bit fADC Int - Slot 10 const FADCMODE = 3 (Int_Int, special) const FADCSLOT_PEPPo3 = 10 const TRSPLIT = 0xea13 # Address of fADC Signal Distribution Module
Reference: Media:PEPPpoHelicityFirmware.pdf Media:PEPPpoHelicityFirmware.docx
TDC
CAEN v775 const int V775_ADD = 0x1190
Reference: Media:V775_manual.pdf
S1 and S2
S1: SIS3801 at addr 0xa40000 S2: SIS3801 at addr 0xa50000
Reference: Media:SIS3801_manual.pdf
TID
A24 Address for TID Module (0x100000 for VME Slot 2) const TRIG_ADDR = 0x100000
Reference: Media:TImaster.pdf
cefdmp/xcefdmp
The event dump utility (cefdmp) can display, in a readable ASCII format, events from the data files.
Syntax
% cefdmp [filename] [-o object] [-t tag] [-u uniquetag] [-s start] [-e end] [-d dictionary] [-x] % xcefdmp [same]
Options
o specify the source object name (CODA component name) t select specified tag number or name (full path in event structure) u select specified unique tag, independent of location in the event s number of first record in file to dump e number of last record in file to dump d specify dictionary for obtaining tag names and titles x hex dump of integers (default is decimal)
cedit and dbedit
Use cedit and/or dbedit to modify CODA database.
Issues and FAQ