Difference between revisions of "Spring 2021 - Rebuilding Photogun"

From Ciswikidb
Jump to navigation Jump to search
Line 20: Line 20:
  
 
===Fix pucks===
 
===Fix pucks===
 +
* Inspect and mic pucks against series 30 series dwg

Revision as of 07:48, 6 April 2021

Other jobs

Replace cathode electrode

  • leak test large grain Nb cathode/ceramic/flange assembly
  • fiducialize Nb cathode to 10" flange (old method glued fiducials)
  • (maybe) fiducialize existing 10" flange to HV chamber
  • vent HV chamber, remove cathode electrode, searching for puck tab
  • fiducialize anode to HV chamber
  • align cathode to anode
  • align LM to cathode (after venting depo)
  • align HV to chamber Y and re-align laser for retro-reflection

Replace depo schneedle

  • Make (2) SS schneedle w/o silver plating, replace depo chamber silver plated schneedle media:ACC2003000-0219 schneedle.pdf
  • NF3 leak value => leave as-is
  • align mask, fix w/ two set screws
  • replace K source with Alvatec Sb source?

Fix pucks

  • Inspect and mic pucks against series 30 series dwg