Difference between revisions of "200 kV Polarized Gun"

From Ciswikidb
Jump to navigation Jump to search
Line 1: Line 1:
* The 200 kV gun (R30-3 with spherical electrode and 18" gun HVC) was installed in CEBAD during SAD 2023.
+
* The 200 kV gun (R30-3 with spherical electrode and 18" gun HVC) was installed in CEBAF during SAD 2023.
  
* This gun performed was designed din terms of vacuum, and no field emission at 200 kV.
+
* This gun performed as designed in terms of vacuum, and high voltage: no field emission at 200 kV after conditioning with Kr to ~240 kV.
* It had two problems:
+
* It has two problems:
 
* a) The beam waist is ~ 6 cm downstream of the GaAs wafer, compared to ~ 40 cm from the Tee electrode 14" HVC R28-2 gun operated in CEBAF for years at 130 kV.
 
* a) The beam waist is ~ 6 cm downstream of the GaAs wafer, compared to ~ 40 cm from the Tee electrode 14" HVC R28-2 gun operated in CEBAF for years at 130 kV.
 
* b) It was a not possible to obtain the laser retro-reflection.
 
* b) It was a not possible to obtain the laser retro-reflection.
 
* The gun was then removed from the injector and replaced with the R28-2 gun.
 
* The gun was then removed from the injector and replaced with the R28-2 gun.
 
* The SAD 2023 links below capture the planning for fixing these problems in thee R30-3 gun (which will then be version R30-4) and for installing it in May 2024.
 
* The SAD 2023 links below capture the planning for fixing these problems in thee R30-3 gun (which will then be version R30-4) and for installing it in May 2024.
 +
 +
==SAD 2024 Planning Meetings==
 +
 +
* Jan 05, 2024
 +
* Jan 10, 2024
  
 
==200 kV Gun SAD 2023 Installation Links==
 
==200 kV Gun SAD 2023 Installation Links==

Revision as of 14:38, 9 January 2024

  • The 200 kV gun (R30-3 with spherical electrode and 18" gun HVC) was installed in CEBAF during SAD 2023.
  • This gun performed as designed in terms of vacuum, and high voltage: no field emission at 200 kV after conditioning with Kr to ~240 kV.
  • It has two problems:
  • a) The beam waist is ~ 6 cm downstream of the GaAs wafer, compared to ~ 40 cm from the Tee electrode 14" HVC R28-2 gun operated in CEBAF for years at 130 kV.
  • b) It was a not possible to obtain the laser retro-reflection.
  • The gun was then removed from the injector and replaced with the R28-2 gun.
  • The SAD 2023 links below capture the planning for fixing these problems in thee R30-3 gun (which will then be version R30-4) and for installing it in May 2024.

SAD 2024 Planning Meetings

  • Jan 05, 2024
  • Jan 10, 2024

200 kV Gun SAD 2023 Installation Links

SAD 2023 Planning Meetings

Links