Difference between revisions of "Bubble Chamber Beam Test August 2015"

From Ciswikidb
Jump to navigation Jump to search
 
(49 intermediate revisions by 2 users not shown)
Line 1: Line 1:
= '''Run Plan''' =
+
= '''Emittance Measurements, September 3, 2015''' =
  
This is a test of 5D line, the chamber is off.
+
* We measured (normalized) emittance and Twiss parameters for the horizontal and vertical planes as a function of momentum (6.7, 7.7 and 8.3 MeV/c).
 +
 
 +
* The result from previous measurements is summarized in JLAB-TN-14-004 (February 2014): ''Transverse Beam Characterization in the CEBAF 5 MeV Region''
 +
[[media:TN-14-004.pdf]] [[media:TN-14-004.docx]]
 +
 
 +
 
 +
 
 +
 
 +
= '''Beam Charge'''=
 +
 
 +
* '''Beam Current:'''
 +
 
 +
The following command dumps the archived current readback from Keithley Picoammeter K6485 and the BCM0L02 Gigatronics readback to a file:
 +
 +
mySampler -b "2015-08-14 20:30:00" -s 1s -n 10800 IBC0L02Current IFY5D04K6485dataRead > BubbleCur_Aug14.txt
 +
 
 +
* Data file of beam current (10 µA) on Bubble Radiator/Dump (August 14, 20:30 - 23:30): [[media:BubbleCur_Aug14.txt]]
 +
 
 +
* Data file of beam current (10 µA) on Bubble Radiator/Dump (August 13, 20:30 - 23:30): [[media:BubbleCur_Aug13.txt]]
 +
 
 +
 
 +
 
 +
 
 +
= '''Maximum ¼ Cryo-unit Gradients''' =
 +
 
 +
 
 +
 
 +
 
 +
= '''Calibrate ¼ Cryo-unit Gradients''' =
 +
 
 +
 
 +
 
 +
 
 +
= '''Beam Energy'''=
 +
 
 +
* Approximate energy of the beam coming into 0L02 is 500 keV.
 +
 
 +
* Cryomodule 0L02 adds the rest of the beam energy. The cavities in 0L02 (7 and 8) are 0.5 meters long. Their "GMES"s are measured in MV/m.
 
   
 
   
# Tue, August 11: Turn on gun, commission new lasers, beam to FC1 (Joe Grames).
+
* Energy contributed by 0L02, then, is 0.5 * (GMES of cavity 7 + GMES of cavity 8), assuming both cavities are on crest.
# Wed, August 12: Beam to FC2 and 5D dump (Yan, Riad).
+
 
# Thursday, August 13: Check beam optics to 5D (Chris). Measure beam current (Riad).
+
* Beam kinetic energy estimate is T_estimate = 500 keV + 0.5 * (GMES-0L02-7 + GMES-0L02-8).
# Friday, August 14: Mott and photocathode Analyzing power (Joe ,Riad).
+
 
# Saturday, August 15: Find maximum energy and measure beam energy (Jay, Riad).
+
 
 +
 
 +
* '''To measure the beam energy:'''
 +
 
 +
1. Use the above T_estimate formula to determine initial setpoint for MDL0L02 into 5D (bubble chamber) line.  
 +
 
 +
BdL in 5D line [G-cm] = 1412 * T_estimate
 +
 
 +
2. Make sure 5D horizontal correctors are all set to zero BdL.
 +
 
 +
3. Send beam and center it on viewers 5D00 and 5D01 by adjusting MDL0L02 and vertical correctors in 0L and 5D region.  
 +
 
 +
4. Once beam is centered on both viewers, use the formula below to determine beam energy:
 +
 
 +
 
 +
Beam momentum p [MeV/c] = (MDL0L02-BdL – 372) / 1412. The earth's field (and other environmental fields) contribution is about 372 G-cm.  
 +
 
 +
Total Energy E [MeV] = Sqrt( p<sup>2</sup> * c<sup>2</sup> + m<sup>2</sup> * c<sup>4</sup> ) ≈ p * c. The electron mass m = 0.511 MeV/c<sup>2</sup>.
 +
 
 +
Beam Kinetic Energy T [MeV] = E – m * c<sup>2</sup> ≈ p * c – m * c<sup>2</sup>.
 +
 
 +
 
 +
 
 +
* '''To change beam kinetic energy by a known increment:'''
 +
 
 +
Assume we want to increase beam kinetic energy by 0.1 MeV, then follow these steps:
 +
 
 +
* Increase GMES of cavity 8 (GMES-0L02-8) by 0.2 MV/m.
 +
 
 +
* Increase MDL0L02 field by the ratio 0.1/T<sub>0</sub>
 +
 
 +
* Send beam and center it on viewers 5D00 and 5D01 by adjusting MDL0L02 and vertical correctors in 0L and 5D region.  
 +
 
 +
* Once beam is centered on both viewers, use the formula above to determine beam energy.
 +
 
 +
 
 +
 
 +
 
 +
= '''Bubble Chamber Digital Camera with Beam in Injector''' =
 +
 
 +
* On Tuesday August 11, around 9:30 - 10:05 pm, we tested the bubble chamber sensitivity to gammas with beam (6.3 MeV/c) to Faraday Cup 2 and 5D line. We did not see any thing on camera, none of the pixels showed any activity, nothing.
 +
 
 +
These were the beam conditions:
 +
# 30 µA CW at CEBAF Faraday Cup 2
 +
# 10 µA CW at 5D Line radiator/dump
 +
# 10 µA CW at 5D Line Faraday Cup

Latest revision as of 14:37, 11 September 2015

Emittance Measurements, September 3, 2015

  • We measured (normalized) emittance and Twiss parameters for the horizontal and vertical planes as a function of momentum (6.7, 7.7 and 8.3 MeV/c).
  • The result from previous measurements is summarized in JLAB-TN-14-004 (February 2014): Transverse Beam Characterization in the CEBAF 5 MeV Region

media:TN-14-004.pdf media:TN-14-004.docx



Beam Charge

  • Beam Current:

The following command dumps the archived current readback from Keithley Picoammeter K6485 and the BCM0L02 Gigatronics readback to a file:

mySampler -b "2015-08-14 20:30:00" -s 1s -n 10800 IBC0L02Current IFY5D04K6485dataRead > BubbleCur_Aug14.txt



Maximum ¼ Cryo-unit Gradients

Calibrate ¼ Cryo-unit Gradients

Beam Energy

  • Approximate energy of the beam coming into 0L02 is 500 keV.
  • Cryomodule 0L02 adds the rest of the beam energy. The cavities in 0L02 (7 and 8) are 0.5 meters long. Their "GMES"s are measured in MV/m.
  • Energy contributed by 0L02, then, is 0.5 * (GMES of cavity 7 + GMES of cavity 8), assuming both cavities are on crest.
  • Beam kinetic energy estimate is T_estimate = 500 keV + 0.5 * (GMES-0L02-7 + GMES-0L02-8).


  • To measure the beam energy:

1. Use the above T_estimate formula to determine initial setpoint for MDL0L02 into 5D (bubble chamber) line.

BdL in 5D line [G-cm] = 1412 * T_estimate

2. Make sure 5D horizontal correctors are all set to zero BdL.

3. Send beam and center it on viewers 5D00 and 5D01 by adjusting MDL0L02 and vertical correctors in 0L and 5D region.

4. Once beam is centered on both viewers, use the formula below to determine beam energy:


Beam momentum p [MeV/c] = (MDL0L02-BdL – 372) / 1412. The earth's field (and other environmental fields) contribution is about 372 G-cm. 
Total Energy E [MeV] = Sqrt( p2 * c2 + m2 * c4 ) ≈ p * c. The electron mass m = 0.511 MeV/c2.
Beam Kinetic Energy T [MeV] = E – m * c2 ≈ p * c – m * c2.


  • To change beam kinetic energy by a known increment:

Assume we want to increase beam kinetic energy by 0.1 MeV, then follow these steps:

  • Increase GMES of cavity 8 (GMES-0L02-8) by 0.2 MV/m.
  • Increase MDL0L02 field by the ratio 0.1/T0
  • Send beam and center it on viewers 5D00 and 5D01 by adjusting MDL0L02 and vertical correctors in 0L and 5D region.
  • Once beam is centered on both viewers, use the formula above to determine beam energy.



Bubble Chamber Digital Camera with Beam in Injector

  • On Tuesday August 11, around 9:30 - 10:05 pm, we tested the bubble chamber sensitivity to gammas with beam (6.3 MeV/c) to Faraday Cup 2 and 5D line. We did not see any thing on camera, none of the pixels showed any activity, nothing.

These were the beam conditions:

  1. 30 µA CW at CEBAF Faraday Cup 2
  2. 10 µA CW at 5D Line radiator/dump
  3. 10 µA CW at 5D Line Faraday Cup