Difference between revisions of "Kerr - June 1, 2016"

From Ciswikidb
Jump to navigation Jump to search
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
Here is an outline to get started...let's evolve as project proceeds...
+
Here is an outline to get started...let's evolve as project proceeds...[[media:160601_Kerr_Outline.docx]]
  
Part I – Become familiar with polarized light and optical measurements
+
=== Part I – Become familiar with polarized light and optical measurements ===
  
Basic Setup
+
;Basic Setup
 +
* Find low power (<20 mW) laser and parts needed to do this:
 +
* Send light to power meter to get familiar with power level and control
 +
* Add a polarizer to define plane of polarization
 +
* Add an analyzer to find maximum and minimum e.g. “Law of Malus”
 +
* Between cross polarizers vary angle of half- and quarter- wave plates
 +
* Compare the different configurations to Thorlabs optical polarimeter
  
1. Find low power (<20 mW) laser and parts needed to do this:
+
;Photodiode and Scope Setup
 +
* Find a photodiode and scope to see intensity signal in real time
 +
* Define polarization and analyzing planes of crossed polarizers
 +
* Convince yourself that intervening half-wave plate can leak light
 +
* Insert Hinds AOM and demonstrate it works as a fast wave plate
 +
* Use lock-in amplifier to extract the AOM amplitude using photodiode
 +
* Compare the configuration to the Thorlabs optical polarimeter
  
2. Send light to power meter to get familiar with power level and control
+
=== Part II – Test Kerr signal using a magnetized foil ===
  
3. Add a polarizer to define plane of polarization
+
;Basic Setup – Analyze linear polarization angle from iron foil
 +
* Find iron foils, pucks and permanent magnets
 +
* Reflect laser off un-magnetized iron foil between cross-polarizers
 +
* Use (variable) waveplate to test sensitivity to linear polarization plane
 +
* Test signal as permanent magnets are added (measure field) to foil
 +
* Move magnets relative to foil, test sensitivity
 +
* Learn how to demagnetize the foil
  
4. Add an analyzer to find maximum and minimum e.g. “Law of Malus”
+
;Advanced Setup – Photodiode and Scope Setup
 +
* Try Thorlabs polarimeter or fast photodiode to measure signal
 +
* Repeat basic setup using the Hinds modulator; vary the foil magnetization
 +
* Evolve sophistication of setup to best resolve plane of polarization
  
5. Between cross polarizers vary angle of half- and quarter- wave plates
+
=== Part III – Kerr measurements of magnetized puck ===
  
6. Compare the different configurations to Thorlabs optical polarimeter
+
;Setup – Integrate your diagnostic at Magnet Measurement Facility (MMF)
 +
* Become familiar with the new magnet coil geometry, field
 +
* Devise a means to add your foil and with geometry like that of photogun
 +
* Move or re-build your Kerr diagnostic at the MMF
  
Photodiode and Scope Setup
+
;Experiment
1. Find a photodiode and scope to see intensity signal in real time
+
* Measure plane of polarization vs. power supply current (magnetic field)
2. Define polarization and analyzing planes of crossed polarizers
+
* With MMF help measure magnetic field at face of iron
3. Convince yourself that intervening half-wave plate can leak light
 
4. Insert Hinds AOM and demonstrate it works as a fast waveplate
 
5. Use lock-in amplifier to extract the AOM amplitude using photodiode
 
6. Compare the configuration to the Thorlabs optical polarimeter
 
 
 
Part II – Test Kerr signal using a magnetized foil
 
 
 
Basic Setup – Analyze linear polarization angle from iron foil
 
1. Find iron foils, pucks and permanent magnets
 
2. Reflect laser off un-magnetized iron foil between cross-polarizers
 
3. Use (variable) waveplate to test sensitivity to linear polarization plane
 
4. Test signal as permanent magnets are added (measure field) to foil
 
5. Move magnets relative to foil, test sensitivity
 
6. Learn how to demagnetize the foil
 
 
 
Advanced Setup – Photodiode and Scope Setup
 
1. Try Thorlabs polarimeter or fast photodiode to measure signal
 
2. Repeat basic setup using the Hinds modulator; vary the foil magnetization
 
3. Evolve sophistication of setup to best resolve plane of polarization
 
 
 
Part III – Kerr measurements of magnetized puck
 
 
 
Setup – Integrate your diagnostic at Magnet Measurement Facility (MMF)
 
1. Become familiar with the new magnet coil geometry, field
 
2. Devise a means to add your foil and with geometry like that of photogun
 
3. Move or re-build your Kerr diagnostic at the MMF
 
 
 
Experiment
 
1. Measure plane of polarization vs. power supply current (magnetic field)
 
2. With MMF help measure magnetic field at face of iron
 

Latest revision as of 12:02, 1 June 2016

Here is an outline to get started...let's evolve as project proceeds...media:160601_Kerr_Outline.docx

Part I – Become familiar with polarized light and optical measurements

Basic Setup
  • Find low power (<20 mW) laser and parts needed to do this:
  • Send light to power meter to get familiar with power level and control
  • Add a polarizer to define plane of polarization
  • Add an analyzer to find maximum and minimum e.g. “Law of Malus”
  • Between cross polarizers vary angle of half- and quarter- wave plates
  • Compare the different configurations to Thorlabs optical polarimeter
Photodiode and Scope Setup
  • Find a photodiode and scope to see intensity signal in real time
  • Define polarization and analyzing planes of crossed polarizers
  • Convince yourself that intervening half-wave plate can leak light
  • Insert Hinds AOM and demonstrate it works as a fast wave plate
  • Use lock-in amplifier to extract the AOM amplitude using photodiode
  • Compare the configuration to the Thorlabs optical polarimeter

Part II – Test Kerr signal using a magnetized foil

Basic Setup – Analyze linear polarization angle from iron foil
  • Find iron foils, pucks and permanent magnets
  • Reflect laser off un-magnetized iron foil between cross-polarizers
  • Use (variable) waveplate to test sensitivity to linear polarization plane
  • Test signal as permanent magnets are added (measure field) to foil
  • Move magnets relative to foil, test sensitivity
  • Learn how to demagnetize the foil
Advanced Setup – Photodiode and Scope Setup
  • Try Thorlabs polarimeter or fast photodiode to measure signal
  • Repeat basic setup using the Hinds modulator; vary the foil magnetization
  • Evolve sophistication of setup to best resolve plane of polarization

Part III – Kerr measurements of magnetized puck

Setup – Integrate your diagnostic at Magnet Measurement Facility (MMF)
  • Become familiar with the new magnet coil geometry, field
  • Devise a means to add your foil and with geometry like that of photogun
  • Move or re-build your Kerr diagnostic at the MMF
Experiment
  • Measure plane of polarization vs. power supply current (magnetic field)
  • With MMF help measure magnetic field at face of iron