Difference between revisions of "Data Acquisition System"
Line 15: | Line 15: | ||
[[Media:DAQ_Timing_20130129.pptx]] | [[Media:DAQ_Timing_20130129.pptx]] | ||
+ | |||
+ | |||
+ | = How to run CODA = | ||
+ | |||
+ | * Log into idaq@opsmdaq0 (It is an accelerator machine!) using the '''idaq''' account and open few terminals. The ''xterm'' command will help you on that | ||
+ | |||
+ | * | ||
+ | |||
+ | in xterm 1: telnet iocmdaq1 | ||
+ | |||
+ | in xterm 2 : platform | ||
+ | Telnet is used to control the status of the run, error messages are appearing here! | ||
+ | |||
+ | *In another terminal type : | ||
+ | in xterm 3 : codamaster | ||
+ | |||
+ | Choose one of the configurations. | ||
+ | |||
+ | [[Image:CodaConfigs4.png||180px]] | ||
+ | |||
+ | When the CODAMASTER panel appears, select ''config'' => ''enable buttons''. | ||
+ | |||
+ | [[Image:Codamaster3.png|290px]] | ||
+ | |||
+ | |||
+ | Select ''ET System'', ''Event Builder'' and ''Event Recorder''. and ''Run Control'' to monitor and operate runs. | ||
+ | After doing that if you will click on ''Get Status'' you will find status of '' Event builder'' ''Event Recorder'' and of the ''ROC1''. Al buttons must be green as the picture is showing. | ||
+ | |||
+ | [[Image:GreenButtons2.png|280px]] | ||
+ | |||
+ | Selecting ''Run control'' the main CODA panel will appear. | ||
+ | |||
+ | |||
+ | [[Image:CODARunControl2.png|700px]] | ||
+ | |||
+ | == Start and Stop a RUN == | ||
+ | After the opening of the Run control panel, select in order: | ||
+ | # ''Sessions'' => ''inj'' | ||
+ | # ''Configurations'' => ''Cool'' => Choose the wanted one | ||
+ | # ''Platform'' => ''Connect'' | ||
+ | # ''Configure'' | ||
+ | # ''Download'' | ||
+ | # ''Prestart'' | ||
+ | # ''Start'' the run | ||
+ | |||
+ | as displayed in the picture: | ||
+ | |||
+ | [[Image:StartRun.png|500px]] | ||
+ | |||
+ | At the end: | ||
+ | <ol start="8"> | ||
+ | <li>''Stop''</li> | ||
+ | </ol> | ||
+ | and if you want to apply a change or you need a new configuration: | ||
+ | <ol start="9"> | ||
+ | <li>''Reset''</li> | ||
+ | </ol> | ||
+ | and start from number 5. When you are applaying a reset, do it twice (suggestion). | ||
+ | |||
+ | == Errors, Warnings and FAQ == | ||
+ | # | ||
+ | |||
+ | == How to use the VME discriminator == | ||
+ | The VME discriminator is the CAEN v895 whic has several possibilities. | ||
+ | It is used in several configuration file but it must be set up correctly. | ||
+ | The configurations used, at the moment, are: | ||
+ | * PEPPo_Sample, PEPPo_Cosmics, Annihilation_Sample, PEPPo_SemiInt | ||
+ | How to use the module, from every directory: | ||
+ | v895_config | ||
+ | |||
+ | An user interface will appear. | ||
+ | |||
+ | [[Image:V895_config.png]] | ||
+ | |||
+ | PMT refer to PEPPO cristal PMTs, A1 and A2 are for annihilation counter and cosmics are for cosmic paddles. | ||
+ | |||
+ | * Set thresholds for all the channels (thresholds are in mV) and select(tick) only channels used. | ||
+ | |||
+ | * To set the number of channels used as to generate one trigger select the ''Majority Level'' (MJL) or coincidence. | ||
+ | |||
+ | MJL = 1 means that, with at least one detector above the threshold, it generates the output signal. | ||
+ | MJL = 3 you need at least 3 detector signals above the thresholds to generate the output signal | ||
+ | |||
+ | For Cosmic and Annihilation configurations MJL set to 2. | ||
+ | |||
+ | To close Coda use the codamaster panel and press ''kill all'' followed by the exit botton under 'configuration'. | ||
+ | |||
+ | |||
+ | == How to use the JLAB VME discriminator == | ||
+ | |||
+ | One can open a GUI in from opsmdaq0 | ||
+ | /opt/idaq/lib/JLabdiscr/GUIDiscrim/src | ||
+ | [[Image:JLABDisc.png]] |
Revision as of 07:41, 28 June 2013
DAQ Hardware
- Electronic Map of Mott Crates (January 29, 2013):
Media:ElectronicsMap_20130129.pdf
Media:ElectronicsMap_20130129.ppt
- Cabling of FADC, Scalers, and TDC (January 29, 2013):
- DAQ Timing (January 29, 2013):
Media:DAQ_Timing_20130129.pptx
How to run CODA
- Log into idaq@opsmdaq0 (It is an accelerator machine!) using the idaq account and open few terminals. The xterm command will help you on that
in xterm 1: telnet iocmdaq1
in xterm 2 : platform
Telnet is used to control the status of the run, error messages are appearing here!
- In another terminal type :
in xterm 3 : codamaster
Choose one of the configurations.
When the CODAMASTER panel appears, select config => enable buttons.
Select ET System, Event Builder and Event Recorder. and Run Control to monitor and operate runs.
After doing that if you will click on Get Status you will find status of Event builder Event Recorder and of the ROC1. Al buttons must be green as the picture is showing.
Selecting Run control the main CODA panel will appear.
Start and Stop a RUN
After the opening of the Run control panel, select in order:
- Sessions => inj
- Configurations => Cool => Choose the wanted one
- Platform => Connect
- Configure
- Download
- Prestart
- Start the run
as displayed in the picture:
At the end:
- Stop
and if you want to apply a change or you need a new configuration:
- Reset
and start from number 5. When you are applaying a reset, do it twice (suggestion).
Errors, Warnings and FAQ
How to use the VME discriminator
The VME discriminator is the CAEN v895 whic has several possibilities. It is used in several configuration file but it must be set up correctly. The configurations used, at the moment, are:
- PEPPo_Sample, PEPPo_Cosmics, Annihilation_Sample, PEPPo_SemiInt
How to use the module, from every directory:
v895_config
An user interface will appear.
PMT refer to PEPPO cristal PMTs, A1 and A2 are for annihilation counter and cosmics are for cosmic paddles.
- Set thresholds for all the channels (thresholds are in mV) and select(tick) only channels used.
- To set the number of channels used as to generate one trigger select the Majority Level (MJL) or coincidence.
MJL = 1 means that, with at least one detector above the threshold, it generates the output signal. MJL = 3 you need at least 3 detector signals above the thresholds to generate the output signal
For Cosmic and Annihilation configurations MJL set to 2.
To close Coda use the codamaster panel and press kill all followed by the exit botton under 'configuration'.
How to use the JLAB VME discriminator
One can open a GUI in from opsmdaq0
/opt/idaq/lib/JLabdiscr/GUIDiscrim/src