Difference between revisions of "Kerr - August 5, 2016"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
[[file:Puckgeometry.jpeg|thumb|upright=2.5|Use this to interpret Excel descriptions.]] | [[file:Puckgeometry.jpeg|thumb|upright=2.5|Use this to interpret Excel descriptions.]] | ||
− | ''' | + | '''1.''' |
+ | '''NEAR Trials with Steel only''' | ||
− | The following | + | The following 'a.' and 'b.' describes measurements done with; |
− | * STEEL puck only | + | * STEEL puck only, {with the exception of a mirror null} |
* Angle between laser and photodiode 38.6 -+2.4 degrees | * Angle between laser and photodiode 38.6 -+2.4 degrees | ||
* The Setup was "NEAR" The solenoid | * The Setup was "NEAR" The solenoid | ||
− | * Center of Optics Stage 58 -+ 1 cm from puck | + | * Center of Optics Stage {between Laser and Photodiode} 58 -+ 1 cm from puck |
− | -->->->[[media:NearSetup.xlsx]] | + | a. -->->->[[media:NearSetup.xlsx]] |
+ | |||
+ | Then Puck stability was investigated | ||
+ | |||
+ | b. -->->-> [[media:Puckchanges.xlsx]] | ||
+ | |||
+ | |||
+ | '''2.''' | ||
+ | '''FAR trials with STEEL and Moly''' | ||
+ | |||
+ | The following file describes measurements done with; | ||
+ | * STEEL and MOLY and a Mirro | ||
+ | * Angle between laser and photodiode 5.31 -+0.45 degrees | ||
+ | * The Setup was "FAR" from The solenoid | ||
+ | * Photodiode 140 cm -+ 2 cm from puck |
Revision as of 17:12, 5 August 2016
1. NEAR Trials with Steel only
The following 'a.' and 'b.' describes measurements done with;
- STEEL puck only, {with the exception of a mirror null}
- Angle between laser and photodiode 38.6 -+2.4 degrees
- The Setup was "NEAR" The solenoid
- Center of Optics Stage {between Laser and Photodiode} 58 -+ 1 cm from puck
a. -->->->media:NearSetup.xlsx
Then Puck stability was investigated
b. -->->-> media:Puckchanges.xlsx
2.
FAR trials with STEEL and Moly
The following file describes measurements done with;
- STEEL and MOLY and a Mirro
- Angle between laser and photodiode 5.31 -+0.45 degrees
- The Setup was "FAR" from The solenoid
- Photodiode 140 cm -+ 2 cm from puck