  • All of the electrode components are on hand and have been dry fitted by Ben Schaumloffel and Bubba Bullard in the TL1337 clean room
  • Bubba and Ben dry fitting the electrode 03.jpg
  • Ball electrode shell, shed, from Pierce end, and back end with holes for easier assembly have been polished
  • This is a picture of the assembled GTS electrode showing the back end with the three holes.
  • Electrode assembly on white R30 back end view zoom.jpg
  • A brand new pure alumina R30 insulator is welded to a 10" CF flange. This flange is the latest design with holes for S&A tooling, and was vacuum fired at 400 C for about 50 hours. Thee flange-ceramic assembly is stored in our HV cabinet (# 9).
  • We should do a leak check of the ceramic assembly.
  • We should have a second pure alumina R30 insulator welded to one of the two remaining 10" CF vacuum fired flanges, as a spare set.
  • The electrode needs to be put together onto the R30 pure alumina assembly.
  • Use dummy puck and hand over electrode-insulator assembly to S&A
  • At this point electrode assembly will be ready for installation in the 18" gun HV chamber