200kV Wien filter - V1
Jump to navigation
Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
Wien specific meetings
- February 1, 2018 - Wien magnet coil follow-up discussion
- January 26, 2018 - Wien magnet coil discussion
Wien filter drawings are up to date (as of June 2017)
- M:\me-group\machie\wien filter
- * main folder has the original fabrication drawings we used.
- * sub folder that has revised version of the original drawings to show the latest as-built changes.
- * sub folder labeled "200KV" that has drawings for the differences in the 200KV wien filter.
- * copy of ECO 1046 that has the analysis of the original vacuum chamber welds.
- * a spreadsheet that lists all the drawings and revision status and applicability.
- Note : we discussed making electrodes from one solid piece of stainless steel instead of five pieces brazed together.
Magnet Design
Jay's TOSCA Modeling
- J. Benesch, "Modeling the SLAC/JLab Wien filter" media:JLab-TN-15-032.pdf
- TOSCA model of air-side magnet assembly, that is (w/o Ni plates in vacuum chamber)
Coil Modified for 20Amp operation
- Replace 2 layer X 14 turn/layer #16 round wire w/ 2 layer X 13 turn/layer #13 square wire
- Maintain 5.00" ID chamber clearance
Magnet Steel Modifications
- Coil fits within existing transverse gap (chamber to steel), but not within existing vertical gap (conflicts electrode ports)
- Channels are cut into upper and lower steel yokes to allow coils to separate further (remove conflicts w/ electrode ports)
- COIL RETAINER PLATES (32893-C-0008) flipped hold coil 0.124" further from mid plane (0.312 - 0.188 inches)
Vacuum Chamber Modifications
- Larger coil width conflicts with magnet mount lugs
- MAGNET MOUNT LUG (32893-C-0024) width reduced from 1.45 to 0.95 inches welded to vacuum chamber body reduced and moved
High Voltage Design
HV feedthroughs (20kV/15A) JLAB DCG 32893-0020
- ISI/MDC version of P/N
- Kurt Lesker version of P/N
Vacuum modifications
- Phil/Danny increased the length of the Electrode Insulator (see JLAB DCG 32893-0112)
- Increased length by 0.25" see for comparison media:171212_longerspacer.pdf
- Phil/Danny increased the length of the HV Connector Spring Guide (see JLAB DCG 32893-0137)
- Increased length by 0.25" see for comparison media:171212_longerguide.pdf