+ | *The version of the Wien filter described here is an improved version of the one tested in UITF beamline with the following changes: | ||
+ | ** 40 kV CeramTec HV feedthroughs (3/4" diameter). | ||
+ | ** Spring-guide to couple to 40 kV feedthrough | ||
+ | ** Spring to match design, but we had to use some that are slightly magnetic. Danny ordered new non-magnetic springs and gave them to Phil. | ||
+ | ** HV tests have been performed without the magnet coil and without the iron yokes | ||
:[[Media:Wien filter modeled in CTS by Gabriel and tested to 20kV per plate in UITF 2019.pptx]] | :[[Media:Wien filter modeled in CTS by Gabriel and tested to 20kV per plate in UITF 2019.pptx]] | ||
+ | :[https://logbooks.jlab.org/entry/3733762 Gabriel's first test with 40 kV feedthroughs applying 19 kV per plate Wien on test stand] |
Revision as of 14:40, 8 October 2019
- The version of the Wien filter described here is an improved version of the one tested in UITF beamline with the following changes:
- 40 kV CeramTec HV feedthroughs (3/4" diameter).
- Spring-guide to couple to 40 kV feedthrough
- Spring to match design, but we had to use some that are slightly magnetic. Danny ordered new non-magnetic springs and gave them to Phil.