Line 5: | Line 5: | ||
::GPT model puts FY solenoids at Jay's TN center lines -/+ 9.8425 cm, should/can they be different? | ::GPT model puts FY solenoids at Jay's TN center lines -/+ 9.8425 cm, should/can they be different? | ||
::What sort of tolerances should be included in simulations? | ::What sort of tolerances should be included in simulations? | ||
− | * | + | * A, B, C slits |
− | * Do we replace chromox screen with a YAG screen | + | :: Use [https://www.lesker.com/newweb/sample_manipulation/linearshifts_lsm-hlsm.cfm linear manipulators]? |
− | * Do we modify how the MS/CP are inserted/retracted | + | :: Use same apertures? |
− | * Replace existing pump with 45 L/sec pump, w/ well located pump out port | + | * View screen |
+ | ::Do we replace chromox screen with a YAG screen? | ||
+ | ::Include with markings or fiducials? | ||
+ | * MS/CP apertures | ||
+ | ::Do we modify how the MS/CP are inserted/retracted? | ||
+ | ::Can we eliminate the CP? | ||
+ | * Vacuum | ||
+ | ::Do we replace the honking 120? L/s pump? Yes! | ||
+ | ::Replace existing pump with 45 L/sec pump, w/ well located pump out port? | ||
* Shaun drawings... | * Shaun drawings... | ||
::[[media:JL0091770 SOLENOID COMPARISONS LEGACY & MFY.pdf]] | ::[[media:JL0091770 SOLENOID COMPARISONS LEGACY & MFY.pdf]] |
Latest revision as of 16:21, 5 February 2020
We'll meet at 9am TL-2236 for chopping chamber, then transition into weekly ME meeting
Chopping Chamber Agenda
- Incorporates new FY 92mm ID solenoids
- GPT model puts FY solenoids at Jay's TN center lines -/+ 9.8425 cm, should/can they be different?
- What sort of tolerances should be included in simulations?
- A, B, C slits
- Use linear manipulators?
- Use same apertures?
- View screen
- Do we replace chromox screen with a YAG screen?
- Include with markings or fiducials?
- MS/CP apertures
- Do we modify how the MS/CP are inserted/retracted?
- Can we eliminate the CP?
- Vacuum
- Do we replace the honking 120? L/s pump? Yes!
- Replace existing pump with 45 L/sec pump, w/ well located pump out port?
- Shaun drawings...
ME Layout Agenda
- Feb 04, 2020 media:BEAMLINELAYOUTFEB04.pdf edits post modellers meeting (add bpm/cor after Y, and swap bpm/corr by A1
- Jan 31, 2020 media:200203_layout.pdf major revision to address setting up the beam line
- First viewer design media:YagViewerHole.pdf
- BPM overview Short media:shortBPM.pdf and Long media:7-52BPM.pdf UITF viewers