Mar 6 2024

From Ciswikidb
Revision as of 10:58, 5 March 2024 by Bruker (talk | contribs)
Jump to navigation Jump to search

Updates

  • Max, Gabriel
    • Repeated lens optimization for MFX2I01 and MFX1I03 to minimize beam size at MDR1I02 and MWF1I04...
      • R30 16°/30°, SW FX lenses
      • recess +0.1 mm, +0 mm, and -0.1 mm compared to nominal
      • produced lens settings at 0.001 pC and used them at 0.340 pC (similar to machine setup strategy)
      • Comparison of R30 16°/30° lens optimization results
      • qualitative shape of curves similar; doing the optimization the other way around would not change the numbers by too much
      • recess affects optimal lens setpoints (unsurprisingly) but causes no unmanageable differences in beam parameters
      • minor emittance increase due to space charge
    • Plan B
    • Test plan for R28 phase space measurement at CEBAF: https://tasklists.jlab.org/bslist/tasks/111123
      • extends Yan's measurement with option for Twiss-parameter fit
      • perfunctory attempt with R30-3 gun last summer gave excessive emittance, likely due to chromox viewer, but better than nothing?