Difference between revisions of "Run Meeting: March 24th, 2020"

From clas12-run
Jump to navigation Jump to search
(Created page with "Back to Run Group F | Daily Run Group F Coordination Meetings 10:00AM Run Meeting, Counting house meeting room (200C) (NOT) '''RC:''' Carlos Ayerbe ==Su...")
 
 
(One intermediate revision by one other user not shown)
Line 9: Line 9:
 
* Summary in the RC Daily Report
 
* Summary in the RC Daily Report
  
 
+
https://logbooks.jlab.org/entry/3808901
 
 
 
 
  
 
==Shutdown Procedures:==
 
==Shutdown Procedures:==
Line 22: Line 20:
 
## Close SVBT112 and open SVBT108 to flush target with Nitrogen.
 
## Close SVBT112 and open SVBT108 to flush target with Nitrogen.
 
## Purge as many times as deemed necessary (I would say twice).
 
## Purge as many times as deemed necessary (I would say twice).
## as the last step, leave target at around 5 psig N2 and '''DO NOT''' close SVBT112.
+
## as the last step, after filling one more time with N2, close all electric inlet valves (SVBT100,SVBT102, SVBT108) and all manual valves on gas bottles and the manifold in the gas pad area, but '''DO NOT''' close SVBT112.
## close all electric valves AND all hand valves on the gas pad.
+
## By leaving SVBT112 open, the target will be replenished with the N2 "purge" gas as long as that holds up, and in any case we avoid a situation where the target could be below atmospheric (surrounding) pressure.
  
 
# Drift region procedure
 
# Drift region procedure
## Flow 30 sccm of pre-mix gas He/CO2 with BOTH bottles open.   
+
## First turn off all RTPC HV
 +
## Reduce drift gas flow to 30 sccm of pre-mix gas He/CO2 with BOTH bottles open.   
  
 
# Electronics
 
# Electronics
## Jiwan will proceed to turn off it remotely. Also he is willing to come if needed. (Stuart mentioned a period of transient during the shut down, so I shouldn't be a problem to access the Hall after 8AM)
+
## We need to turn off the FEU low voltage, '''BUT ONLY AFTER the FMT HV and gas has been shut down!'''
 
+
## Jiwan will proceed to turn it off remotely. Also he is willing to come if needed. (Stuart mentioned a period of transient during the shut down, so I shouldn't be a problem to access the Hall after 8AM)
 
+
## Bob will turn off the blowers
 
 
 
 
 
 
 
 
  
 
==Info==
 
==Info==

Latest revision as of 01:51, 24 March 2020

Back to Run Group F | Daily Run Group F Coordination Meetings

10:00AM Run Meeting, Counting house meeting room (200C) (NOT)

RC: Carlos Ayerbe

Summary of past 24h:

  • Summary in the RC Daily Report

https://logbooks.jlab.org/entry/3808901

Shutdown Procedures:

Welcome to MEDCON6

  1. Target procedure to shut down (Sebastian, with the correction)
    1. empty by closing SVBT100 and opening SVBT112.
    2. Close SVBT108 and open SVBT102, and set MFC104 interface to Nitrogen.
    3. Close SVBT112 and open SVBT108 to flush target with Nitrogen.
    4. Purge as many times as deemed necessary (I would say twice).
    5. as the last step, after filling one more time with N2, close all electric inlet valves (SVBT100,SVBT102, SVBT108) and all manual valves on gas bottles and the manifold in the gas pad area, but DO NOT close SVBT112.
    6. By leaving SVBT112 open, the target will be replenished with the N2 "purge" gas as long as that holds up, and in any case we avoid a situation where the target could be below atmospheric (surrounding) pressure.
  1. Drift region procedure
    1. First turn off all RTPC HV
    2. Reduce drift gas flow to 30 sccm of pre-mix gas He/CO2 with BOTH bottles open.
  1. Electronics
    1. We need to turn off the FEU low voltage, BUT ONLY AFTER the FMT HV and gas has been shut down!
    2. Jiwan will proceed to turn it off remotely. Also he is willing to come if needed. (Stuart mentioned a period of transient during the shut down, so I shouldn't be a problem to access the Hall after 8AM)
    3. Bob will turn off the blowers