Difference between revisions of "Template:ShortTermSchedule-RGK"
Jump to navigation
Jump to search
Line 43: | Line 43: | ||
| valign=top width=50% | | | valign=top width=50% | | ||
− | == '''Run Plan''', ''' | + | == '''Run Plan''', '''Tuesday, Jan. 16 - Wednesday, Jan. 17, 2024'''== |
− | *''' | + | *'''Tuesday Day/Swing''' |
− | :: | + | :: Keep HV for detectors on while we wait for beam to come back. |
− | *'''Tuesday | + | *'''Tuesday Swing/Wednesday Owl''' |
− | |||
− | |||
− | |||
:: Restore the beam (See manuals on [https://github.com/JeffersonLab/clas12-manuals/raw/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], [[Media:clas12moller.pdf|Performing Møller Runs]], and [[Media:HarpScanManual.pdf|Performing Harp Scans]] for details) | :: Restore the beam (See manuals on [https://github.com/JeffersonLab/clas12-manuals/raw/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], [[Media:clas12moller.pdf|Performing Møller Runs]], and [[Media:HarpScanManual.pdf|Performing Harp Scans]] for details) | ||
+ | ::: Turn off (or move to safe) all detector HV | ||
::: '''Ask MCC to take out the half-wave plate''' | ::: '''Ask MCC to take out the half-wave plate''' | ||
::: Steer to tagger dump | ::: Steer to tagger dump | ||
::: Take a Moller Run | ::: Take a Moller Run | ||
::: Steer to FC | ::: Steer to FC | ||
− | :: | + | :: Trigger Tests |
− | + | ::: Notify Valery that trigger tests are about to start. | |
− | + | ::: Take a 10 minute run with trigger rgk_noDC_v1.2_300MeV.trg, PROD67_PIN configuration. | |
− | :: | + | ::: Switch the trigger to rgk_out_v1.1_300MeV.trg. Take a full 200M event run with PROD67_PIN configuration. |
− | + | ::: Switch the trigger to rgk_noDC_v1.1_300MeV.trg. Take a full 200M event run with PROD67_PIN configuration. | |
+ | :: Resume production data with PROD_67 configuration. | ||
''' Taking Production Data ''' | ''' Taking Production Data ''' | ||
− | : Trigger is rgk_noDC_v1. | + | : Trigger is rgk_noDC_v1.1_300MeV.trg ; PROD67 configuration; collect 200M events per run |
: 65 nA beam current for now, though this may change | : 65 nA beam current for now, though this may change | ||
:: - Keep an eye that R1 DC occupancies are <5%, and DAQ livetime ~90% | :: - Keep an eye that R1 DC occupancies are <5%, and DAQ livetime ~90% | ||
Line 137: | Line 136: | ||
|} | |} | ||
− | == Glossary of Triggers == | + | == <font color=Navy> '''Glossary of Triggers'''</font> == |
''' Our current default production trigger is rgk_noDC_v1.1_300MeV.trg.''' | ''' Our current default production trigger is rgk_noDC_v1.1_300MeV.trg.''' | ||
Line 154: | Line 153: | ||
|} | |} | ||
− | == '''Reference Values''' == | + | == <font color=Navy> '''Reference Values''' </font> == |
{| {{TableStyle1}} | {| {{TableStyle1}} | ||
Line 205: | Line 204: | ||
** Compare to Dec 2023: https://logbooks.jlab.org/entry/4238636 | ** Compare to Dec 2023: https://logbooks.jlab.org/entry/4238636 | ||
− | == '''To Do Items''' == | + | == <font color=Navy> '''To Do Items'''</font> == |
− | + | ||
− | |||
* Faraday Cup Calibration | * Faraday Cup Calibration | ||
** Rafo can use beam current scan taken from Sat. Jan. 13, during 13:50 - 14:20 | ** Rafo can use beam current scan taken from Sat. Jan. 13, during 13:50 - 14:20 |
Revision as of 14:30, 16 January 2024
Experiment Coordinator: Annalisa D'Angelo
Run Coordinator: Axel Schmidt (757) 575-7540
PDL: Daniel Carman (757) 876-1789; Office: x5586
Daily RC/OA Meetings at 13:00 in CH Room 200C, and on ZOOM: URL Link
Important Notes
Do NOT change FSD settings without approval from RC or beamline expert!
- Procedure for starting a new run is:
- - "End run"
- - "Cancel"
- - "Reset"
- - "Download"
- - "Prestart"
- - "Go"
This will ensure proper compression of the FADCs and therefore a smaller data rate.
- Shifters should make sure to log every DC trip in a logbook post. Make sure to list WHERE the trip occured.
- In case of medical or fire emergency, call 9-911 from a LANDLINE phone in the Counting House and inform the Crew Chief and RC.
- In case of evacuation of the Counting Room (e.g., due to a fire alarm), grab the shift expert phone and leave the room through the "EXIT" door leading to the parking lot. Do not leave through the hallway! Call the RC once outside so the latter will call MCC to turn the beam OFF to Hall B and inform other Hall B staff members.
- If you have symptoms or a positive COVID test, do NOT come to your shift - instead, inform the PDL and the RC and JLab medical services immediately to arrange replacements.
- Remote shift: If needed, worker shifts can be taken from off-site. Inform the PDL and RC. Also, make sure that you follow the instructions under the "Shift Worker" tab, as you need some lead time to set up!
- Note to Shift Takers:
- Read the ESAD, COO, RSAD, and ERG documents found on the "Current RG-K Run Info" as well as the yellow folder in the counting room. Before you start your first shift on the current experiment, you must sign on the list in the yellow folder. Thereby, you confirm that you have read and understand their content.
- Read at least the previous 24 hours logbook entries to be aware of recent run details and changes;
- Arrive at least 10 minutes early for shift change;
- Refresh the runwiki page/tabs; look over it/them every shift:
- Follow the Shift Expert/Worker tab's instructions.
- Do not spend more than 15-20 min trying to fix a problem. In case of any issue, contact the On-call Experts or the RC.
- Important links
- Recent Changes and Current Issues
- General How-to for beam restoration procedures and Møller runs.
Run Plan, Tuesday, Jan. 16 - Wednesday, Jan. 17, 2024
Taking Production Data
|
General Information
|
DAQ Operation & Related General Information
|
|
Glossary of Triggers
Our current default production trigger is rgk_noDC_v1.1_300MeV.trg.
Trigger | Explanation |
---|---|
rgk_noDC_v1.0_300MeV.trg | DC roads are not in the trigger. Hold off time is 3 us. |
rgk_noDC_v1.1_300MeV.trg | DC roads are not in the trigger. Hold off time is 2 us. |
rgk_noDC_v1.2_300MeV.trg | DC roads are not in the trigger. Hold off time is 1 us. |
rgk_out_v1.1_300MeV.trg | Outbending DC roads, Hold off time is 2 us. |
Reference Values
BPM Settings
|
FSD Thresholds from RG-K
|
Harp Scan References from RG-K
- Tagger (2C24A)
- Jan. 12, 2024 Swing (after attempts to improve beam profile): https://logbooks.jlab.org/entry/4238887
- Jan. 12, 2024 Owl: https://logbooks.jlab.org/entry/4238638 x= -2.0 mm; y= +0.6 mm
- Compare to Dec 2023: https://logbooks.jlab.org/entry/4238622
- 2H01
- Jan. 12, 2024 Swing (after attempts to improve beam profile): https://logbooks.jlab.org/entry/4238889
- Jan. 12, 2024 Owl: https://logbooks.jlab.org/entry/4238673 x= -1.1 mm; y= 0.6 mm
- Compare to Dec 2023: https://logbooks.jlab.org/entry/4234764
- 2C21A
- Jan. 12, 2024 Owl: https://logbooks.jlab.org/entry/4238636 x= -0.4 mm; y= +0.6 mm
- Compare to Dec 2023: https://logbooks.jlab.org/entry/4238636
To Do Items
- Faraday Cup Calibration
- Rafo can use beam current scan taken from Sat. Jan. 13, during 13:50 - 14:20
- Empty target running (with full field)
- Goal is to take > 5% integrated charge, but not until about 2 weeks in
- Prescale on FC cup trigger
- Discuss when to study after we have a plan for Tuesday Jan. 16 down time