Jump to navigationJump to searchLine 17: | Line 17: | ||
# What do we need to do to fix this problem. | # What do we need to do to fix this problem. | ||
+ | -Several things can be done to correct the issue. The least impact (from an operational view) would be to isolate and warm up the turbine temporarily. | ||
# Is this really a problem (I think that this is a big problem) | # Is this really a problem (I think that this is a big problem) | ||
+ | -Absolutely. The bearing gas system isn't yet fully understood. Regardless, a turbine spinning when bearing gas is not active would certainly wear the turbine. | ||
# Why do we think this is a problem (Is bearing gas on during that time) | # Why do we think this is a problem (Is bearing gas on during that time) | ||
+ | -See above. | ||
# Should we be doing something manually? | # Should we be doing something manually? | ||
+ | -For long outages, consider closing the manual valve on the T2 outlet. | ||
# Other questions that we need to make sure we have answered. | # Other questions that we need to make sure we have answered. | ||
+ | |||
== Action Items == | == Action Items == |
Revision as of 11:18, 19 January 2017
Attendance
J. Creel K. Dixon M. Wright R. Norton D. Schleeper S. Radovic
Issue Statement
- When T2 at ESR trips off, the turbine continues to spin much longer than expected. The is a concern that the turbine will be damaged if it does not stop spinning when the inlet valve is closed. On a few occasions, the turbine continued to spin (~500Hz) until the the plant was re-started.
Agenda and Notes
- What do we need to do to fix this problem.
-Several things can be done to correct the issue. The least impact (from an operational view) would be to isolate and warm up the turbine temporarily.
- Is this really a problem (I think that this is a big problem)
-Absolutely. The bearing gas system isn't yet fully understood. Regardless, a turbine spinning when bearing gas is not active would certainly wear the turbine.
- Why do we think this is a problem (Is bearing gas on during that time)
-See above.
- Should we be doing something manually?
-For long outages, consider closing the manual valve on the T2 outlet.
- Other questions that we need to make sure we have answered.
Action Items
- investigate bearing gas process at ESR
- Verify LVDT on turbine inlet valve
- Warm T2. Schedule. Dependent on transfer line.
- Check seating force of T2 inlet valve (require trip?) (verify proper operation)
- Can T2 be isolated to support troubleshooting without damaging turbine or stopping entire CBX?
- Develop plan to isolate CBX in the event T2 must be stopped, and/or CBX must be tripped.
- Verify that we have a spare.
- What is required to check seating force (operationally)?
- Create an alarm that will alert us when turbine inlet valves are closed and turbine speed is > 0.
- drink a beer
- Get the transfer line from CHL operational
- follow-up meeting ~1/20/2017.
- Contact Pete to begin information/data collection, vendors, contacts.